Wavelength-dependent conformational changes in collagen after mid-infrared laser ablation of cornea.

نویسندگان

  • Yaowu Xiao
  • Mingsheng Guo
  • Peng Zhang
  • Ganesh Shanmugam
  • Prasad L Polavarapu
  • M Shane Hutson
چکیده

We ablated porcine corneas with a free electron laser tuned to either 2.77 or 6.45 microm, two matched wavelengths that predominantly target water and protein, respectively. The ejected nonvolatile debris and the crater left behind were examined by circular dichroism, Raman spectroscopy, and scanning electron microscopy to characterize the postablation conformation of collagen proteins. We found near-complete unfolding of collagen secondary and tertiary structure at either ablating wavelength. On the other hand, we found excess fibril swelling and evidence for excess cis-hydroxyproline in the 6.45-microm debris. These results support the hypothesis that the favorable ablative properties of protein-targeting wavelengths rest on selective heating of tissue proteins.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Wavelength-dependent collagen fragmentation during mid-IR laser ablation.

Mid-infrared free-electron lasers have proven adept in surgical applications. When tuned to wavelengths between 6 and 7 microm, such lasers remove defined volumes of soft tissue with very little collateral damage. Previous attempts to explain the wavelength-dependence of collateral damage have invoked a wavelength-dependent loss of protein structural integrity. However, the molecular nature of ...

متن کامل

Enhanced Tissue Ablation Efficiency with a Mid-Infrared Nonlinear Frequency Conversion Laser System and Tissue Interaction Monitoring Using Optical Coherence Tomography

We report development of optical parametric oscillator (OPO)-based mid-infrared laser system that utilizes a periodically poled nonlinear crystal pumped by a near-infrared (NIR) laser. We obtained a mid-infrared average output of 8 W at an injection current of 20 A from a quasi-phase-matched OPO using an external cavity configuration. Laser tissue ablation efficiency is substantially affected b...

متن کامل

Laboratory evaluation of selective in situ refractive cornea collagen shrinkage with continuous wave infrared laser combined with transepithelial collagen cross-linking: a novel refractive procedure

BACKGROUND This research comprised a laboratory evaluation of a novel refractive surgery technique involving sequential corneal subsurface shrinkage-driven reshaping using a continuous wave mid-infrared laser application followed by stiffening via rapid transepithelial higher fluence collagen cross-linking for shape persistence/longevity on cadaver corneas. MATERIALS AND METHODS Ten cadaver c...

متن کامل

Interplay of wavelength, fluence and spot-size in free-electron laser ablation of cornea.

Infrared free-electron lasers ablate tissue with high efficiency and low collateral damage when tuned to the 6-microm range. This wavelength-dependence has been hypothesized to arise from a multi-step process following differential absorption by tissue water and proteins. Here, we test this hypothesis at wavelengths for which cornea has matching overall absorption, but drastically different dif...

متن کامل

Keratoconus experimentally produced in mice using collagenase

Introduction: Keratoconus is a relatively common disease of cornea in which structural changes within the cornea cause it to thin and change to a conical shape and scar at the central portion of cornea. So far, few methods and drug treatments were introduced due to both lack of accepted animal models to induce experimental keratoconus and limitation of research in human considering ethical issu...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Biophysical journal

دوره 94 4  شماره 

صفحات  -

تاریخ انتشار 2008