The composition of tribofilms produced on metal-on-metal hip bearings.

نویسندگان

  • James Hesketh
  • Michael Ward
  • Duncan Dowson
  • Anne Neville
چکیده

Following wear testing in a hip simulator, the bearing surfaces of 36 mm metal on metal total hip replacements showed the formation of tribochemical layers. These layers were investigated in a transmission electron microscope, and analysis was performed using electron energy loss spectroscopy, energy dispersive x-rays and selected area electron diffraction. The tribofilm formed at the edge of the wear scar was 100 s of nanometres thick and contained cobalt sulphide particles embedded within. The film itself was rich in carbon, and appeared to contain no long range graphitic ordering when analysed with electron energy loss spectroscopy, and the spectra gathered from the tribofilm closely resembled those collected from amorphous carbon. The location at which the most substantial tribological layers formed may be explained by the formation of a blunt wedge at the edge of the wear scar following conformal changes to the bearing surfaces.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Influence of simulator kinematics on the wear of metal-on-metal hip prostheses.

There is now considerable interest in metal-on-metal bearings for hip prostheses. Extremely low wear rates (0.1 mm3/10(6) cycles) have been reported in some simulator studies, while in vivo studies, although still very low, have shown wear rates of the order of 1 mm3/10(6) cycles. The aim of this study was to compare wear rates of metal-on-metal bearings in two hip simulators with different kin...

متن کامل

The increase in cobalt release in metal-on-polyethylene hip bearings in tests with third body abrasives

Hypersensitivity reactions in patients receiving metal-on-metal hip replacements have been attributed to corrosion products as observed by elevated cobalt and chromium ions in the blood. Although the majority of cases are reported in metal-on-metal, incidences of these reactions have been reported in the metal-on-polyethylene patient population. To date, no in vitro study has considered cobalt ...

متن کامل

The Epidemiology of Total Hip Arthroplasty Bearing Surface Use in the United States

Introduction: Metal on conventional ultra-high molecular weight polyethylene (UHMWPE) bearings have produced excellent long-term results in total hip arthroplasty (THA), with 20 year survivorship of almost 80%. However, the consequences of bearing surface wear, including osteolysis and aseptic loosening, have been a leading cause of late revision THA, especially in younger, more active patients...

متن کامل

Ceramic-on-metal bearings in total hip replacement: whole blood metal ion levels and analysis of retrieved components.

This study reports on ceramic-on-metal (CoM) bearings in total hip replacement. Whole blood metal ion levels were measured. The median increase in chromium and cobalt at 12 months was 0.08 microg/1 and 0.22 microg/1, respectively, in CoM bearings. Comparable values for metal-on-metal (MoM) were 0.48 microg/1 and 0.32 microg/1. The chromium levels were significantly lower in CoM than in MoM bear...

متن کامل

Levels of metal ions after small- and large-diameter metal-on-metal hip arthroplasty.

Metal-on-metal (MOM) bearings for hip arthroplasty are increasing in popularity. Concern remains, however, regarding the potential toxicological effects of the metal ions which these bearings release. The serum levels of cobalt and chromium in 22 patients who had undergone MOM resurfacing arthroplasty were compared with a matched group of 22 patients who had undergone 28 mm MOM total hip arthro...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Biomaterials

دوره 35 7  شماره 

صفحات  -

تاریخ انتشار 2014