Characteristics and outcomes of patients receiving new and replacement implantable cardioverter-defibrillators: results from the NCDR.
نویسندگان
چکیده
BACKGROUND Little is known about the clinical features, procedural risks, or survival of patients receiving replacement versus new implantable cardioverter-defibrillators (ICDs). METHODS AND RESULTS Entries in the National Cardiovascular Data Registry (NCDR) ICD Registry from 2005 through 2010 were eligible for inclusion (n=463,978). Baseline demographic data, clinical information, and procedural variables were compared between patients receiving new (n=359,993; 77.6%) and replacement (n=103,985; 22.4%) ICDs and entered into a propensity match model to determine adjusted survival rates. Patients receiving replacement ICDs were older (70.7 versus 67.5 years of age) and more likely to have atrial fibrillation (41.8% versus 31.4%; P<0.001) and ventricular tachycardia (60.5% versus 33.9%; P<0.001) compared with patients receiving new ICDs. Median battery life was only 4.6 years (25%-75% interquartile range, 3.7-5.8) for all replaced devices, 5.8 (25%-75% interquartile range, 4.2-7.5) for single-chamber, 5.1 (25%-75% interquartile range, 4.1-6.1) for dual-chamber, and 3.9 (25%-75% interquartile range, 3.2-4.6) years for biventricular devices. Patients receiving replacement ICDs had lower rates of index admission complications (0.9% versus 3.2%; P<0.001) but greater risk for death compared receiving patients receiving new ICDs in unadjusted analysis (hazard ratio, 1.18; 95% confidence interval, 1.16-1.20; P<0.0001) and after propensity-score matching (hazard ratio, 1.28; 95% confidence interval, 1.25-1.30; P<0.0001). CONCLUSIONS Patients receiving replacement ICDs are older and at greater risk for death compared with those receiving initial ICD implants. The battery life of initial ICDs is shorter than previously reported.
منابع مشابه
Survival of patients with implantable cardioverter defibrillators in the era of remote-monitoring: the 5000-foot, high-altitude view.
Large randomized trials have demonstrated unequivocally that implantable cardioverter defibrillators (ICDs) improve outcome for individuals with defined clinical characteristics known to be associated with a high risk of ventricular arrhythmias. However, less is known about outcomes of patients receiving ICDs in the “real world.” The National Cardiovascular Data Registry provides extensive and ...
متن کاملIncidence and Costs Related to Lead Damage Occurring Within the First Year After a Cardiac Implantable Electronic Device Replacement Procedure.
BACKGROUND Inadvertent damage to leads for transvenous pacemakers, implantable cardioverter-defibrillators, and cardiac resynchronization therapy defibrillators is an important complication associated with generator-replacement procedures. We sought to estimate the incidence and costs associated with transvenous lead damage following cardiac implantable electronic device replacement. METHODS ...
متن کاملTHE EFFECT OF NURSE-PEER-LED SUPPORT INTERVENTION ON QUALITY OF LIFE IN PATIENTS WITH AN IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR: A RANDOMIZED CLINICAL TRIAL
Background & Aims: Nowadays, the quality of life and how coping and treatment of patients with an implantable cardiac defibrillator has led to concern and attempts to reduce or eliminate the problems of these patients in the people who provide health care services. This study aimed to determine the effect of nurse-peer-led support intervention on quality of life in patients with an implantable ...
متن کاملAntithrombotic Therapy and Outcomes After ICD Implantation in Patients With Atrial Fibrillation and Coronary Artery Disease: An Analysis From the National Cardiovascular Data Registry (NCDR)®
BACKGROUND Management of antithrombotic agents after implantable cardioverter defibrillator implantation is challenging, particularly among patients with atrial fibrillation and coronary artery disease. METHODS AND RESULTS Using data from National Cardiovascular Data Registry(®) Implantable Cardioverter Defibrillator Registry(™) linked with Medicare claims data, we identified 25 180 patients ...
متن کاملThe effect of education based on Orem’s self-care model on emotional reactions in patients with Implantable Cardioverter Defibrillator (ICD)
Abstract Aim. The purpose of this study was to examine the effect of education based on Orem’s self-care model on emotional reactions in people with Implantable Cardioverter Defibrillator (ICD). Background. ICD shock is unpredictable and associated with physical pain. After receiving shock, some patients find serious psychological problems such as anxiety, depression and stress. According to Or...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Circulation. Cardiovascular quality and outcomes
دوره 6 4 شماره
صفحات -
تاریخ انتشار 2013