3D image-guided robotic needle positioning system for small animal interventions.

نویسندگان

  • Jeffrey S Bax
  • Christopher S R Waring
  • Shi Sherebrin
  • Shawn Stapleton
  • Thomas J Hudson
  • David A Jaffray
  • James C Lacefield
  • Aaron Fenster
چکیده

PURPOSE This paper presents the design of a micro-CT guided small animal robotic needle positioning system. In order to simplify the robotic design and maintain a small targeting error, a novel implementation of the remote center of motion is used in the system. The system has been developed with the objective of achieving a mean targeting error of <200 μm while maintaining a high degree of user friendliness. METHODS The robot is compact enough to operate within a 25 cm diameter micro-CT bore. Small animals can be imaged and an intervention performed without the need to transport the animal from one workspace to another. Not requiring transport of the animal reduces opportunities for targets to shift from their localized position in the image and simplifies the workflow of interventions. An improved method of needle calibration is presented that better characterizes the calibration using the position of the needle tip in photographs rather than the needle axis. A calibration fixture was also introduced, which dramatically reduces the time requirements of calibration while maintaining calibration accuracy. Two registration modes have been developed to correspond the robot coordinate system with the coordinate system of the micro-CT scanner. The two registration modes offer a balance between the time required to complete a registration and the overall registration accuracy. The development of slow high accuracy and fast low accuracy registration modes provides users with a degree of flexibility in selecting a registration mode best suited for their application. RESULTS The target registration error (TRE) of the higher accuracy primary registration was TRE(primary) = 31 ± 12 μm. The error in the lower accuracy combined registration was TRE(combined) = 139 ± 63 μm. Both registration modes are therefore suitable for small-animal needle interventions. The targeting accuracy of the robotic system was characterized using targeting experiments in tissue-mimicking gelatin phantoms. The results of the targeting experiments were combined with the known calibration and needle deflection errors to provide a more meaningful measure of the needle positioning accuracy of the system. The combined targeting errors of the system were 149 ± 41 μm and 218 ± 38 μm using the primary and combined registrations, respectively. Finally, pilot in vivo experiments were successfully completed to demonstrate the performance of the system in a biomedical application. CONCLUSIONS The device was able to achieve the desired performance with an error of <200 μm and improved repeatability when compared to other designs. The device expands the capabilities of image-guided interventions for preclinical biomedical applications.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Modular Surgical Robotic System for Image Guided Percutaneous Procedures

This paper presents a robotic system for precise needle insertion under radiological guidance for surgical interventions and for delivery of therapy. It is extremely compact and is compatible with portable X-ray units and computer tomography scanners. The system presents a modular structure comprising a global positioning module, a miniature robotic module, and a radiolucent needle driver modul...

متن کامل

A networked modular hardware and software system for MRI-guided robotic prostate interventions

Magnetic resonance imaging (MRI) provides high resolution multi-parametric imaging, large soft tissue contrast, and interactive image updates making it an ideal modality for diagnosing prostate cancer and guiding surgical tools. Despite a substantial armamentarium of apparatuses and systems has been developed to assist surgical diagnosis and therapy for MRI-guided procedures over last decade, t...

متن کامل

Three-dimensional ultrasound-guided robotic needle placement: an experimental evaluation.

BACKGROUND Clinical use of image-guided needle placement robots has lagged behind laboratory-demonstrated robotic capability. Bridging this gap requires reliable and easy-to-use robotic systems. METHODS Our system for image-guided needle placement requires only simple, low-cost components and minimal, entirely off-line calibration. It rapidly aligns needles to planned entry paths using 3D ult...

متن کامل

Transperineal prostate intervention: robot for fully automated MR imaging--system description and proof of principle in a canine model.

The study was approved by the animal care and use committee. The purpose of the study was to prospectively establish proof of principle in vivo in canines for a magnetic resonance (MR) imaging-compatible robotic system designed for image-guided prostatic needle intervention. The entire robot is built with nonmagnetic and dielectric materials and in its current configuration is designed to perfo...

متن کامل

3D Steering of a Flexible Needle by Visual Servoing

This paper presents a robotic control method for 3D steering of a beveled-tip flexible needle. The solution is based on a new duty-cycling control strategy that makes possible to control three degrees of freedom of the needle. A visual servoing control scheme using two orthogonal cameras observing a translucent phantom is then proposed to automatically steer a needle toward a 3D target point. E...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Medical physics

دوره 40 1  شماره 

صفحات  -

تاریخ انتشار 2013