Detection of anti-infliximab antibodies is impacted by antibody titer, infliximab level and IgG4 antibodies: a systematic comparison of three different assays

نویسندگان

  • Joana Afonso
  • Susana Lopes
  • Raquel Gonçalves
  • Paulo Caldeira
  • Paula Lago
  • Helena Tavares de Sousa
  • Jaime Ramos
  • Ana Rita Gonçalves
  • Paula Ministro
  • Isadora Rosa
  • Ana Isabel Vieira
  • Rosa Coelho
  • Patrícia Tavares
  • João Soares
  • Ana Lúcia Sousa
  • Diana Carvalho
  • Paula Sousa
  • João Pereira da Silva
  • Tânia Meira
  • Filipa Silva Ferreira
  • Cláudia Camila Dias
  • Yehuda Chowers
  • Shomron Ben-Horin
  • Fernando Magro
چکیده

BACKGROUND There is scant information on the accuracy of different assays used to measure anti-infliximab antibodies (ADAs), especially in the presence of detectable infliximab (IFX). We thus aimed to evaluate and compare three different assays for the detection of IFX and ADAs and to clarify the impact of the presence of circulating IFX on the accuracy of the ADA assays. METHODS Blood samples from 79 ulcerative colitis (UC) patients treated with infliximab were assessed for IFX levels and ADAs using three different assays: an in-house assay and two commercial kits, Immundiagnostik and Theradiag. Sera samples with ADAs and undetectable levels of IFX were spiked with exogenous IFX and analyzed for ADAs. RESULTS The three assays showed 81-96% agreement for the measured IFX level. However, the in-house assay and Immundiagnostik assays detected ADAs in 34 out of 79 samples, whereas Theradiag only detected ADAs in 24 samples. Samples negative for ADAs with Theradiag, but ADA-positive in both the in-house and Immundiagnostik assays, were positive for IFX or IgG4 ADAs. In spiking experiments, a low concentration of exogenous IFX (5 µg/ml) hampered ADA detection with Theradiag in sera samples with ADA levels of between 3 and 10 µg/ml. In the Immundiagnostik assay detection interference was only observed at concentrations of exogenous IFX higher than 30 µg/ml. However, in samples with high levels of ADAs (>25 µg/ml) interference was only observed at IFX concentrations higher than 100 µg/ml in all three assays. Binary (IFX/ADA) stratification of the results showed that IFX+/ADA- and IFX-/ADAs+ were less influenced by the assay results than the double-positive (IFX+/ADAs+) and double-negative (IFX-/ADAs-) combination. CONCLUSIONS All three methodologies are equally suitable for measuring IFX levels. However, erroneous therapeutic decisions may occur when patients show double-negative (IFX-/ADAs-) or double-positive (IFX+/ADAs+) status, since agreement between assays is significantly lower in these circumstances.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of Immunoblotting and ELISA for Detection of Anti-Ganglioside Antibodies in Children with Guillain-Barre Syndrome

Background: Anti-ganglioside antibody assays are widely used for diagnosis of autoimmune peripheral neuropathies. Objective: This study aimed to determine serum levels of anti-ganglioside antibodies in children with Guillain-Barre syndrome by immunoblotting technique and compare the results with those obtained by ELISA method. Method: In this investigation, 50 children with Guillain-Barre syndr...

متن کامل

Development of an ELISA Test for Detection of Anti FMD Virus Type A87/IRN Antibody Using Irradiated Antigen

Background and Aims: The aim of this study was application of gamma irradiated FMDV antigen for liquid phase blocking sandwich ELISA (B-ELISA) to quantify guinea pig anti FMDV type A87/IRN antibody. Methods: FMDV type A87/IRN was propagated to a titer of 107.5/ml TCID50 and then irradiated by gamma irradiator. The irradiated 146 S antigen was purified by sucrose gradient centrifugation after in...

متن کامل

The Effects of Recombinant Human Erythropoietin (rHuEPO) on Antihuman Lymphocyte Antibodies Titer in Sensitized Rats

Erythropoietin (EPO) was first known as a factor for red blood cell proliferation and differentiation. Recent studies show the effects of EPO on immune system. In this study the antihuman leukocyte antibody (anti-HLA) titer were determined in five groups of rats, which had been sensitized with human lymphocyte. Also, the effects of stimulation's frequency and dose of recombinant human erythropo...

متن کامل

Applying conserved peptides of NS1 Protein of avian influenza virus to differentiate infected from vaccinated chickens

Avian influenza (AI) is a highly contagious disease in poultry and outbreaks can have dramatic economic and health implications. For effective disease surveillance, rapid and sensitive assays are needed to detect antibodies against AI virus (AIV) proteins. In order to support eradication efforts of avian influenza (AI) infections in poultry, the implementation of “DIVA” vaccination strategies, ...

متن کامل

Production and Evaluation of Polyclonal Rabbit Anti-Human p53 Antibody Using Bacterially Expressed Glutathione S-transferase-p53 fusion protein

p53 is a key tumor suppressor gene that is targeted for inactivation during human tumorigenesis. In this study, we produced and characterized polyclonal antihuman p53 antibody. The cDNA encoding the completehuman p53 protein was cloned into pGEX-4T-1 and expressed in Escherichia coli as a fusion protein with Schistosoma japonicum glutathione S-transferase (GST). The rabbits were immunized...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 9  شماره 

صفحات  -

تاریخ انتشار 2016