BACKGROUND Arterial blood gas (ABG) analysis is useful in evaluation of the clinical condition of critically ill patients; however, arterial puncture or insertion of an arterial catheter may cause many complications. The aim of this study was to determine whether venous blood gas (VBG) values can be used as an alternative to arterial blood gas measurements in patients under mechanical ventilation. MATERIALS AND METHODS This study was carried out on patients admitted to the Intensive Care Unit of Kashan Beheshti Hospital. Blood for VBG analysis was obtained from the cubital vein, while for ABG analysis blood was taken simultaneously from the radial artery. ABG and VBG samples were obtained simultaneously, and indexes of pH, PCO2, HCO3, base excess (BE), PO2 and O2 saturation level were analyzed. RESULTS A total of 102 pair of simultaneous venous and arterial blood samples were obtained from 102 patients (mean age 58.4±21.5 years). Seventy (69%) were males. The mean difference between arterial and venous values was 0.04 for pH, 5.6 mm/Hg for PCO2, -0.32 mmol/l for HCO3, -1.03 mmol/l for BE, 53.6 mm/Hg for PO2, and 23.5% for O2 saturation. The Pearson correlation coefficients between arterial and venous values for pH, PCO2, HCO3, BE, PO2 and O2 saturation were 0.874, 0.835, 0.768, 0.810, 0.287, and 0.310, respectively. Linear regression equations for the estimation of pH, PCO2, HCO3, BE, PO2 and O2 saturation were as follows: arterial pH=1.927+0.745×venous pH [r=0.801, p<0.001]; PCO2=6.470+0.706×venous PCO2 [r=0.835, p<0.001]; arterial HCO3=7.455+0.681×venous HCO3 [r=0.768, p<0.001]; arterial BE=-0.952+0.736×venous BE [r=0.810, p<0.001]; arterial PO2=70.374+0.620×venous PO2 [r=0.287, p=0.003]; arterial venous saturation= 89.753+0.082×venous O2 saturation [r=0.317, p=0.001]. CONCLUSION Venous blood gases, especially pH, Base excess, and PCO2 levels have relatively good correlation with ABG values. Because this correlation is not close, VBG cannot substitute ABG in mechanically ventilated patients.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Correlation of central venous and arterial blood gas measurements in mechanically ventilated trauma patients.

HYPOTHESIS Central venous blood gas (VBG) measurements of pH, PCO2, and base excess can be substituted for the same values obtained from an arterial blood gas (ABG) analysis in mechanically ventilated trauma patients, obviating the need for arterial puncture. DESIGN AND SETTING Prospective comparison of 99 sets of VBGs and ABGs at a level 1 academic trauma center. PATIENTS A consecutive sam...

متن کامل

Correlation of End-Tidal Carbon Dioxide with Arterial Carbon Dioxide in Mechanically Ventilated Patients

BACKGROUND Patients undergone mechanical ventilation need rapid and reliable evaluation of their respiratory status. Monitoring of End-tidal carbon dioxide (ETCO2) as a surrogate, noninvasive measurement of arterial carbon dioxide (PaCO2) is one of the methods used for this purpose in intubated patients. OBJECTIVES The aim of the present trial was to study the relationship between end-tidal C...

متن کامل

End-tidal Carbon Dioxide Measurements in Unintentional Non-Fire-Related Carbon Monoxide Poisoning

Background: Poisoning with carbon monoxide occurs occasionally worldwide, and the gold diagnostic standard is to measure carboxyhemoglobin level in the blood. This study investigated the correlation between carboxyhemoglobin and the end-tidal carbon dioxide levels in 50 patients with carbon monoxide poisoning. Methods: We recruited 50 volunteer patients who had been admitted to the Emergency S...

متن کامل

Continuous fiberoptic arterial and venous blood gas monitoring in hemorrhagic shock.

STUDY OBJECTIVE To compare the performance of continuous fiberoptic blood gas monitoring with standard, intermittent blood gas sampling in the measurement of arterial and central venous blood gases during marked hemodynamic changes. DESIGN Prospective, consecutive, enrollment, experimental study. SETTING Research laboratory at a university medical center. PARTICIPANTS Seven anesthetized, ...

متن کامل

Safe intrahospital transport of critically ill ventilator-dependent patients.

STUDY OBJECTIVE To determine whether manual ventilation during intrahospital transport of mechanically ventilated critically ill patients results in blood gas and/or hemodynamic abnormalities. DESIGN A single-blind prospective study evaluated arterial blood gas, blood pressure, heart rate, and arrhythmia changes during mechanical ventilation and manual transport ventilation. SETTING Univers...