Accuracy of Working Length Determination Using Tri Auto Zx & Protaper Instruments: An In Vitro Study

نویسنده

  • Niranjan Desai
چکیده

Aim and objectives: To assess the accuracy of Tri Auto ZX as an apex locator and its automatic apical reverse mechanism (AAR) set at 0.5, 1 and 1.5mm using Pro-Taper instruments. Materials and Methods: Forty-five freshly extracted single rooted human teeth were used and divided into three groups: (1) Teeth prepared using AAR set at 0.5mm (2) Teeth prepared using AAR set at 1mm (3) Teeth prepared using AAR set at 1.5mm.Tri Auto ZX (J. Morita, Kyoto, Japan) was activated to auto mode and biomechanical preparation was carried out using protaper instruments till size F3 for each group. The F3 instrument was stabilized at the position and roots were ground longitudinally until exposure of the instrument. Under stereomicroscope the distance between the file tip and apical foramen was measured. Results: The results showed the mean value for Groups was 0.4617mm, 0.8976mm and 1.5277mm respectively. Statistical analysis between the groups revealed that Groups I and III showed no statistical difference i.e (p<0.05). Group II showed the significance at 5% significance level. Conclusion: Tri Auto ZX showed to be an acceptable device for determining root canal length and instrumentation. Using a preset distance set at 0.5 and 1.5mm were more accurate than set at 1mm.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of Working Length Determination Using Apex Locator and Conventional Radiography in Curved Canals-an In Vitro Study

Introduction: The exact measurement of the root canal length is of great importance in root canal therapy. Although, determination of the root canal length through radiography is the most common method, recently electronic apex locators are being used to determine working length and decrease the number of radiographs. The purpose of this study was to compare the accuracy of an electronic apex l...

متن کامل

Evaluation of the accuracy of two apex locators in endodontic treatment and retreatments: an ex vivo study

Introduction: Working length determination is important in successful endodontic treatment and retreatment.This study evaluated the accuracy of two electronic apex locators Root ZX and Raypex&reg;6 (EALs) in determining the electronic working length (EWL) of the root canals in endodontic treatment and retreatment. Materials and Methods: Access cavities were prepared on forty extracted, singl...

متن کامل

In vitro evaluation of the accuracy of two new electronic apex locators in root canal length determination

In vitro evaluation of the accuracy of two new electronic apex locators in root canal length determination Dr. Hasheminia, S.M.* - Dr. Jafari, N.** *Associate Professor of Endodontics Dept., Faculty of Dentistry, Isfahan University of Medical Sciences. ** Dentist. Abstract Background & Aim: Radiography is still the common method of measuring working length in root canal therapy. While, gag refl...

متن کامل

Accuracy of an Electronic Apex Locator for Working Length Determination in Primary Anterior Teeth

OBJECTIVES Correct determination of working length is an important step for success of endodontic therapy. Conventional radiography has limitations in providing the accurate location of apical foramen. For this reason, electronic apex locators (EALs) were developed to shorten the treatment time and decrease the radiation dose. The aim of this study was to evaluate the accuracy of Root ZX EAL fo...

متن کامل

Accuracy of Working Length Determination using NovApex and Root-ZX Apex Locators: An in vitro Study.

INTRODUCTION This ex vivo study evaluated the accuracy of the Root-ZX electronic apex locator (EAL) (J. Morita, Tokyo, Japan) and the NovApex (Forum Technologies, Rishon Lezion, Israel) in determining the working length (WL) during endodontic treatment. MATERIALS AND METHODS Forty extracted single-rooted human teeth were selected for this study. The actual WL was measured with visual techniqu...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2012