Evaluation of an ODS column modified with zwitterionic/nonionic mixed surfactants and its application to direct injection determination of inorganic anions.

نویسندگان

  • Takuya Hasegawa
  • Tomonari Umemura
  • Akira Koide
  • Koichi Chiba
  • Yuji Ueki
  • Kin-ichi Tsunoda
  • Hiroki Haraguchi
چکیده

An octadecylsilica (ODS) column modified with zwitterionic/nonionic mixed surfactants was evaluated for the direct injection determination of inorganic anions in biological fluids by ion chromatography. A zwitterionic surfactant (sulfobetaine-type) and a nonionic surfactant (polyoxyethylene-type) were used for a stationary-phase modification. When aqueous electrolyte solutions with concentrations of sub-mM to several mM were used as a mobile phase, the zwitterionic surfactant coated on the ODS surface exhibited unique separation selectivity for ionic species, while the nonionic surfactant coated on the ODS might have formed a hydrophilic network over the ODS surface and restricted matrix proteins from adsorbing on the stationary phase. Consequently, the mixed surfactant-modified column system allowed an efficient ion chromatographic separation of inorganic anions as well as a size-exclusive removal of column-fouling proteins. This separation system was applied to the direct injection determination of UV-absorbing anions in human saliva. The detection limits for nitrite, nitrate, iodide and thiocyanate were 3.1, 2.7, 4.5 and 25 microM, respectively, with UV detection at 210 nm (injection volume; 20 microl), and their relative standard deviations for 5 replicate measurements of saliva samples spiked with 100 microM each of those anions were 1.4, 0.9, 2.2 and 5.5%, respectively.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Direct injection determination of theophylline and caffeine in blood serum by high-performance liquid chromatography using an ODS column coated with a zwitterionic bile acid derivative.

An ODS column dynamically coated with zwitterionic bile acid derivative, 3-[(3-cholamidopropyl)-dimethylammonio]-1-propanesulfonate (CHAPS), was evaluated for direct injection determination of drugs in blood serum by HPLC. Polar functional groups such as sulfonate, ammonium and the three hydroxyl groups in CHAPS protruding towards an aqueous mobile phase formed a hydrophilic layer over the ODS ...

متن کامل

بررسی کارایی زئولیت‌های کلینوپتی‌لولایت اصلاح‌شده با سورفکتانت‌های هگزا‌دسیل‌تری‌متیل آمونیوم کلراید و nستیل پیریدینیوم بروماید در حذف نیترات از محلول‌های آبی

Background and Objectives: Toxic contaminants such as inorganic anions cause water pollution and create some potential risks to human health and the environment. Nitrate as an inorganic anion is one of the most important sources of pollutants for surface and underground waters. Regarding adsorptive properties of zeolite, it is widely used to absorb water and wastewater pollutants. The aim of th...

متن کامل

Chiral Separation of Basic and Zwitterionic Drugs by Highly Sulfated Cyclodextrins Using Short-End Injection Capillary Electrophoresis Highly Sulfated Cyclodextrins Using Short-End Injection Capillary Electrophoresis

Due to high resolution power of sulfated cyclodextrins (HS-CDs), utilization of these selectors for chiral resolution of 7 basic and 2 zwitterionic drugs have been examined. Experiments were performed on a HP3DCE instrument equipped with an on-column diode array UV absorbance detector. Fused silica capillaries with an inner diameter of 50 ?m, an outer diameter of 365 ?m, and a total length of 4...

متن کامل

Chiral Separation of Basic and Zwitterionic Drugs by Highly Sulfated Cyclodextrins Using Short-End Injection Capillary Electrophoresis Highly Sulfated Cyclodextrins Using Short-End Injection Capillary Electrophoresis

Due to high resolution power of sulfated cyclodextrins (HS-CDs), utilization of these selectors for chiral resolution of 7 basic and 2 zwitterionic drugs have been examined. Experiments were performed on a HP3DCE instrument equipped with an on-column diode array UV absorbance detector. Fused silica capillaries with an inner diameter of 50 ?m, an outer diameter of 365 ?m, and a total length of 4...

متن کامل

The Influence of Bicomponent Mixed Surfactants on Drop/Interface Coalescence

Effects of binary mixtures of ionic/nonionic (sodium dodecyl sulfate/2-heptanol or 1-decanol) and nonionic/nonionic surfactants (2-heptnol/1-decanol) on drop/interface coalescence of water drops in a continuous n-heptane phase were examined. The drop size reduced appreciably and the multi-step coalescence was suppressed finally as the concentration of each of the constituting components</em...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Analytical sciences : the international journal of the Japan Society for Analytical Chemistry

دوره 21 8  شماره 

صفحات  -

تاریخ انتشار 2005