Short-term clinical outcome and dosimetric comparison of tandem and ring versus tandem and ovoids intracavitary applicators

نویسندگان

  • John K. Ma
  • Waleed F. Mourad
  • Robert Allbright
  • Satyaseelan Packianathan
  • Leslie M. Harrell
  • Edmund Chinchar
  • Alex Nguyen
  • Srinivasan Vijayakumar
چکیده

PURPOSE To compare the short-term toxicity and dosimetry of tandem and ring (TR), and tandem and ovoid (TO) applicators in treatment of gynecologic malignancy. MATERIAL AND METHODS Following pelvic external beam radiation therapy (EBRT), a total of 52 computed tomography-based plans from 13 patients with cervical cancer (FIGO IB2-IIIB) were evaluated for HDR brachytherapy. Prescription was 7 Gy to the ICRU point A for four weekly fractions. Gastrointestinal and genitourinary toxicities were evaluated. Clinical target volume (CTV) and organs at risk were delineated on CT scans. Bladder, rectum, and sigmoid mean doses and D2cc were calculated. Treatment time and irradiated tissue volume were compared. Percent of CTV receiving 100% (CTV100%) of the prescribed dose as well as the percent of the prescription dose covering 90% of the CTV (D90) were evaluated. RESULTS Gastrointestinal and genitourinary toxicities were not different between TO and TR applicators. No significant differences in the dose to the right and left point A, or the left point B were observed. TO delivered a higher dose to right point B. Organs at risk doses were similar between the two applicators, except mean rectal dose was lower for TO applicator. Overall, TO treats a larger tissue volume than TR. Mean treatment time was shorter for TR. Tumor coverage (D90 and CTV100%) was equivalent between TO and TR applicators. CONCLUSION Although TO treats a larger tissue volume than TR, short-term toxicities and tumor coverage are similar. Long-term clinical outcomes will be elucidated with longer follow up period.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Developing a Verification and Training Phantom for Gynecological Brachytherapy System

Introduction Dosimetric accuracy is a major issue in the quality assurance (QA) program for treatment planning systems (TPS). An important contribution to this process has been a proper dosimetry method to guarantee the accuracy of delivered dose to the tumor. In brachytherapy (BT) of gynecological (Gyn) cancer it is usual to insert a combination of tandem and ovoid applicators with a complicat...

متن کامل

Does help structures play a role in reducing the variation of dwell time in IPSA planning for gynaecological brachytherapy application?

PURPOSE To report our experience of dosimetric comparison of IPSA and manual plans, with a focus on the use of help structures (HS) during optimization. MATERIAL AND METHODS 33 patients who underwent MR image-based HDR intracavitary-brachytherapy for cervix cancer based on GYN-ESTRO recommendations were selected for evaluation. Tandem/ovoid (T/O) and Vienna applicators were used. HS of diamet...

متن کامل

Uterine perforation during intracavitary brachytherapy for carcinoma of the cervix.

To cite: Prabhakar GS, Revannasiddaiah S, Susheela SP, et al. BMJ Case Reports Published online: 13 December 2012 doi:10.1136/bcr-2012007830 DESCRIPTION Following a seemingly straightforward procedure to place the necessary applicators (comprising the central tandem into the uterine cavity, and the right and the left ovoids into the lateral vaginal fornices), this patient of cervical-carcinoma,...

متن کامل

Direction Modulated Brachytherapy for Treatment of Cervical Cancer. II: Comparative Planning Study With Intracavitary and Intracavitary-Interstitial Techniques.

PURPOSE To perform a comprehensive comparative planning study evaluating the utility of the proposed direction modulated brachytherapy (DMBT) tandem applicator against standard applicators, in the setting of image guided adaptive brachytherapy of cervical cancer. METHODS AND MATERIALS A detailed conceptual article was published in 2014. The proposed DMBT tandem applicator has 6 peripheral gro...

متن کامل

The variability of applicator position among high dose rate intracavitary brachytherapy applications in cervical cancer patients treated with ring & tandem applicators.

OBJECTIVE To evaluate the interindividual and intraindividual applicator position variability in high dose rate ring and tandem intracavitary brachytherapy applications in locally advanced cervical cancer. PATIENTS AND METHODS Eight patients with locally advanced cervical cancer formed the study population. They had been treated in Dokuz Eylül University Department of Radiation Oncology betwe...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 7  شماره 

صفحات  -

تاریخ انتشار 2015