A randomized, fellow eye, comparison of keratometry, aberrometry, tear film, axial length and the anterior chamber depth after eye rubbing in non-keratoconic eyes

نویسندگان

  • Jordan V. Chervenkoff
  • Elizabeth Hawkes
  • Gabriela Ortiz
  • Deborah Horney
  • Mayank A. Nanavaty
چکیده

BACKGROUND To investigate the effect of eye rubbing on keratometry (K), aberrometry, tear film break-up-time (TFBUT) and anterior chamber depth (ACD). METHODS Volunteers without any corneal pathology or dry eyes were randomised to rubbing in one eye and the fellow-eye was control. Eye rubbing was performed for 2 min. Primary outcomes studied were anterior and posterior K changes. Secondary outcomes were changes in TFBUT, axial length (AL) & ACD, K changes in various zones, asphericity and aberrometry. Pre and post rubbing K, aberrometry, ACD and TFBUT were assessed in a predetermined sequence. The relationship of the above parameters to axial length (AL) was also assessed. Astigmatism was analysed using vector analysis. RESULTS Pre versus post rubbing, anterior flatter K further flattened (42.51 ± 1.52 D vs. 42.36 ± 1.53 D, p = 0.003) and the changes to J0 vector in central cornea (-0.16 ± 0.26 D vs. -0.27 ± 0.33 D, p = 0.038) suggested change to against-the-rule (ATR) astigmatism. There was significant change in Z2+2 polynomial following rubbing. We found a positive correlation between axial length and change in posterior K (r = 0.335, p = 0.020). The TFBUT reduced following eye rubbing (15.3 s vs. 13.9 s, p = 0.0001). There was a positive correlation between AL and increase in ACD post rubbing (r = 0.300, p = 0.038). There was a positive correlation between ACD and change in mean posterior K (r = 0.305, p = 0.035). CONCLUSIONS In healthy eyes, following eye rubbing, there is a significant change in TFBUT and central anterior K changes towards ATR astigmatism. Longer eyes had more changes in posterior K and ACD. Whereas, eyes with deeper ACD showed more steepness of posterior K. TRIAL REGISTRATION ClinicalTrials.gov ID: NCT02131740.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Biometric Values of Affected and Fellow Eyes in Patients with Acute Attack of Primary Angle Closure

Background: It has been estimated that 67 million people worldwide are affected with a primary glaucoma and that one-third have primary angle closure glaucoma. We aimed to determine the biometric differences between the eyes of patients with acute attack of primary angle closure and their non-involved fellow eyes. Methods: Twenty eight patients with acute attack of primary angle closure were re...

متن کامل

Myopia following penetrating keratoplasty for keratoconus.

The frequent occurrence of spherical myopia after penetrating keratoplasty for keratoconus is partly the result of the excessive dioptric power of the grafted cornea which occurs when the diameter selected for the donor button is greater than the diameter of the host incision. This excessive power could be reduced by eliminating disparity between the diameters of the graft and host. To determin...

متن کامل

Biometric relationships of ocular components in esotropic amblyopia.

PURPOSE To investigate the contribution of the individual ocular components, i.e. anterior chamber depth, lens thickness and vitreous chamber depth, to total axial length in patients with esotropic amblyopia. METHODS The study population consisted of 74 children, aged between 5 and 8 years: thirty-seven patients with esotropic amblyopia and 37 healthy volunteers (control group). The participa...

متن کامل

New comparative clinical and biometric findings between acute primary angle-closure and glaucomatous eyes with narrow angle.

PURPOSE To compare, clinically and biometrically, affected and fellow acute primary angle-closure (APAC) eyes and glaucomatous eyes with narrow angle (NA). METHODS Comparative case series; 30 patients with APAC and 27 glaucomatous patients with NA were evaluated. Keratometry (K), central corneal thickness (CCT), lens thickness (LT), axial length (AL) and anterior chamber depth (ACD) were meas...

متن کامل

Axial Length and Corneal Curvature in Anisometropic Amblyopia in Nepalese Children

Background: Purpose/Aim: To assess ocular parameters in Nepalese children with severe anisometropic amblyopia. Methods: This was a hospital-based cross-sectional analytical study conducted in a tertiary eye center in Nepal. Twentyone children aged 7-12 years with severe anisometropic amblyopia (>3D of anisometropia) were included in the study. Relevant demographic and clinical data were obtaine...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 4  شماره 

صفحات  -

تاریخ انتشار 2017