Diagnosing Small Hepatic Cysts on Multidetector CT: an Additional Merit of Thinner Coronal Reformations
نویسندگان
چکیده
OBJECTIVE We wanted to validate the additional merit of the thinner coronal reformation images from multidetector CT (MDCT) for making the diagnosis of hepatic cysts. MATERIALS AND METHODS For the 90 benign hepatic cysts confirmed on MRI, the transverse (5-mm thickness) and additional coronal (2-mm thickness) reformation images from MDCT were compared with each other in terms of the Hounsfield units (HUs) and the size of each hepatic cyst. RESULTS THE ATTENUATIONS (MEAN: 17.2 HUs, standard deviation: ± 14.4) on the thinner coronal images were significantly lower than those (mean: 40.7 HUs; standard deviation: ± 20.6) on the thicker transverse images for the small hepatic cysts (≤ 10 mm on the transverse image, p < 0.01). Twenty-three (79%) of the 29 cysts between 5 mm and 10 mm and 21 (51%) of 41 lesions up to 5 mm showed a mean HU value of 20 or less on the coronal reformation images. CONCLUSION By reducing the partial volume effect, routine coronal reformation of MDCT with a thinner section thickness can provide another merit for making a confidential diagnosis of many small sub-centimeter hepatic cysts, and these small cysts are not easily characterized on the conventional transverse images.
منابع مشابه
Using multidetector row computed tomography to diagnose and stage pancreatic carcinoma: the problems and the possibilities.
The sensitivity of computed tomography (CT) in the diagnosis of pancreatic neoplasms and accurate tumor staging has significantly been improved by the use of thin-section multi-detector row CT techniques. Greater table speed, improved tube cooling, high resolution imaging and the possibility of isotropic voxels have led to optimal multiplanar reconstruction in any arbitrary plane and particular...
متن کاملFracture detection in the cervical spine with multidetector CT: 1-mm versus 3-mm axial images.
BACKGROUND AND PURPOSE Multidetector CT imaging of the cervical spine performed with submillimeter collimation allows for the production of excellent quality multiplanar reformations and reconstructed axial images at any chosen section thickness. Currently there is no consensus on what images need to be reviewed for accurate diagnosis of cervical spine fractures. Our study assesses whether 1-mm...
متن کاملOptimization of multiplanar reformations from isotropic data sets acquired with 16-detector row helical CT scanner.
Institutional review board approval and waiver of consent were obtained for the patient component of this retrospective HIPAA-compliant study. By using an anthropomorphic phantom and metal oxide semiconductor field effect transistor detectors, radiation dose was determined for one eight-detector row and two 16-detector row computed tomographic (CT) protocols. A custom phantom was scanned by usi...
متن کاملValue of coronal reformations in the CT evaluation of acute head trauma.
BACKGROUND AND PURPOSE Routine axial CT images may not be ideally suited for detecting ICH in transversely oriented locations such as the floor of the anterior and middle cranial fossas and vertex. This study was performed to evaluate whether coronal reformations improve detection of ICH in NCCT performed for head trauma. MATERIALS AND METHODS All patients undergoing a first NCCT in the ED fo...
متن کاملCan MRI replace CT in evaluating semicircular canal dehiscence?
BACKGROUND AND PURPOSE Patients with symptoms of semicircular canal dehiscence often undergo both CT and MR imaging. We assessed whether FIESTA can replace temporal bone CT in evaluating patients for SC dehiscence. MATERIALS AND METHODS We retrospectively reviewed 112 consecutive patients (224 ears) with vestibulocochlear symptoms who underwent concurrent MR imaging and CT of the temporal bon...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 12 شماره
صفحات -
تاریخ انتشار 2011