A comparison of roughness parameters and friction coefficients of aesthetic archwires.

نویسندگان

  • Philippa Rudge
  • Martyn Sherriff
  • Dirk Bister
چکیده

AIM Compare surface roughness of 'aesthetic' nickel-titanium (NiTi) archwires with their dynamic frictional properties. METHODS Archwires investigated were: four fully coated tooth coloured [Forestadent: Biocosmetic (FB) and Titanol Cosmetic (FT); TOC Tooth Tone (TT); and Hawley Russell Coated Superelastic NiTi (HRC)]; two partially coated tooth coloured [DB Euroline Microcoated (DB) and TP Aesthetic NiTi (TP)]; two rhodium coated [TOC Sentalloy (TS) and Hawley Russell Rhodium Coated Superelastic NiTi (HRR)]; and two controls: stainless steel [Forestadent Steel (FS)] and NiTi archwire [Forestadent Titanol Superelastic (FN)]. Surface roughness [profilometry (Rugosurf)] was compared with frictional coefficients for archwire/bracket/ligature combinations (n = 10). Analysis of variance, Sidak's multiple comparison of means, and Spearman's correlation coefficient were used for analysis. RESULTS Roughness coefficients were from low to high: FB; FN; TT; FS; TS; HRR; FT; DB; TP; HRC. Friction coefficients were from low to high: TP; FS; FN; HRR; FT; DB; FB; HRC; TS; TT. Coated archwires generally exhibited higher friction than uncoated controls. TP had the lowest friction but this was not statistically significant (P < 0.05). Friction of tooth coloured coated archwires were significantly different for some wires. Spearman's correlation did not demonstrate consistency between surface roughness (R a) and dynamic friction. CONCLUSIONS Aesthetic archwires investigated had either low surface roughness or low frictional resistance but not both properties simultaneously. Causes for friction are likely to be multifactorial and do not appear to be solely determined by surface roughness (measured by profilometry). For selecting the most appropriate aligning archwire, both surface roughness and frictional resistance need to be considered.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of the Effect of an Experimental Herbal versus Fluoridated Mouthwash on Frictional Resistance and Surface Roughness between Orthodontic Brackets and Two Types of Archwire: In Vitro Study

Introduction: The present study aimed to evaluate an experimental herbal mouthwash, as compared to sodium fluoride mouthwash on the frictional resistance and surface roughness between brackets and two rectangular archwire types. Methods: A total of 60 premolar׳s brackets engaged with 0.019×0.025 archwires made of stainless steel and nickel-titanium alloys were used in this study. The samples we...

متن کامل

A comparative in vitro study of frictional resistance between lingual brackets and stainless steel archwires.

Friction between archwires and labial brackets has received considerable attention; however, information on the frictional behaviour of commercially available lingual brackets is limited. The aim of this study was to investigate the frictional resistance resulting from a combination of lingual orthodontic brackets (7th Generation, STb, Magic, and In-Ovation L) and stainless steel archwires at 0...

متن کامل

Surface characteristics of retrieved coated and nickel-titanium orthodontic archwires.

OBJECTIVE The purpose of this study was to investigate the effects of oral fluids and archwire-bracket friction on the surface characteristics of NiTi alloy orthodontic archwires with/without aesthetic coating, in vivo for 2-3 months. MATERIALS AND METHODS Different cross-sections of NiTi Archwires (DENTSPLY GAC International) and Titanol Cosmetic Archwires (FORESTADENT® USA Inc.) were examin...

متن کامل

The effect of Teflon coating on the resistance to sliding of orthodontic archwires.

Teflon is an anti-adherent and aesthetic material. The aim of this study was to evaluate, in vitro, the influence of Teflon coating on the resistance to sliding (RS) of orthodontic archwires. For this purpose, Teflon-coated archwires were examined using frictional resistance tests by means of a universal testing machine and compared with conventional uncoated wires. Twelve types of archwires wi...

متن کامل

A new esthetic fiber-reinforced polymer composite resin archwire: a comparative atomic force microscope (AFM) and field-emission scanning electron microscope (FESEM) study

BACKGROUND Fiber-reinforced polymer composite (FRPC) archwires could provide an esthetic solution to conventional orthodontic archwires. This study was carried out with the following aims: (1) to compare the sliding friction of FRPC archwire with nickel titanium archwire using various archwire-bracket combinations and (2) to determine the correlation between surface roughness and friction of th...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • European journal of orthodontics

دوره 37 1  شماره 

صفحات  -

تاریخ انتشار 2015