Photometric measurements of red blood cell aggregation: light transmission versus light reflectance.
نویسندگان
چکیده
Red blood cell (RBC) aggregation is the reversible and regular clumping in the presence of certain macromolecules. This is a clinically important phenomenon, being significantly enhanced in the presence of acute phase reactants (e.g., fibrinogen). Both light reflection (LR) and light transmission (LT) from or through thin layers of RBC suspensions during the process of aggregation are accepted to reflect the time course of aggregation. It has been recognized that the time courses of LR and LT might be different from each other. We aim to compare the RBC aggregation measurements based on simultaneous recordings of LR and LT. The results indicate that LR during RBC aggregation is characterized by a faster time course compared to simultaneously recorded LT. This difference in time course of LR and LT is reflected in the calculated parameters reflecting the overall extent and kinetics of RBC aggregation. Additionally, the power of parameters calculated using LR and LT time courses in detecting a given difference in aggregation are significantly different from each other. These differences should be taken into account in selecting the appropriate calculated parameters for analyzing LR or LT time courses for the assessment of RBC aggregation.
منابع مشابه
Visible light induced photocatalytic degradation of direct red 23 and direct brown 166 by InVO4-TiO2 nanocomposite
The effect of various parameters (pH, irradiation time, nanophotocatalyst dosages and temperature) on photocatalytic degradation of Direct Red 23 (DR 23) and Direct Brown 166 (DB 166) using pure InVO4 and InVO4-TiO2 nanocomposite were investigated under visible light irradiation. InVO4 and InVO4-TiO2 wer...
متن کاملVisible light induced photocatalytic degradation of direct red 23 and direct brown 166 by InVO4-TiO2 nanocomposite
The effect of various parameters (pH, irradiation time, nanophotocatalyst dosages and temperature) on photocatalytic degradation of Direct Red 23 (DR 23) and Direct Brown 166 (DB 166) using pure InVO4 and InVO4-TiO2 nanocomposite were investigated under visible light irradiation. InVO4 and InVO4-TiO2 wer...
متن کاملMeasurement of cell aggregation characteristics by analysis of laser-backscattering in a microfluidic rheometry
The aggregation characteristics of red blood cells (RBCs) are known as important factors in the microvascular flow system, and increased RBC aggregation has been observed in various pathological diseases, such as thrombosis and myocardial infarction. This paper describes a simple microfluidic device for measuring the RBC aggregation by integrating a microfluidic slit rheometry and laser-backsca...
متن کاملS(VO)2 monitoring.
nurse specialist at Swedish Medical Center in Seattle, Wash. lengths in the red and infrared spectra through an optical fiber to illuminate the blood. The red blood cells absorb various amounts of light depending on the amounts of oxygenated and deoxygenated hemoglobin that are present. The light reflected by the blood cells is transmitted through a second optical fiber to the photodetector, wh...
متن کاملNanostructured AgBr loaded TiO2: An efficient sunlight active photocatalyst for degradation of Reactive Red 120
The AgBr loaded TiO2 catalyst was prepared by a feasible approach with AgBr and tetraisopropyl orthotitanate and characterized by BET surface area measurement, diffuse reflectance spectra (DRS), scanning electron microscope (SEM), energy dispersive spectra (EDS), X-ray diffraction (XRD), transmission electron microscope (TEM) and atomic force microscope (AFM) analysis. The results of characteri...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of biomedical optics
دوره 14 5 شماره
صفحات -
تاریخ انتشار 2009