Predictive value of electrocardiographic T-wave morphology parameters and T-wave peak to T-wave end interval for sudden cardiac death in the general population.

نویسندگان

  • Kimmo Porthan
  • Matti Viitasalo
  • Lauri Toivonen
  • Aki S Havulinna
  • Antti Jula
  • Jani T Tikkanen
  • Heikki Väänänen
  • Markku S Nieminen
  • Heikki V Huikuri
  • Christopher Newton-Cheh
  • Veikko Salomaa
  • Lasse Oikarinen
چکیده

BACKGROUND Previous population studies have found an association between electrocardiographic T-wave morphology parameters and cardiovascular mortality, but their relationship to sudden cardiac death (SCD) is not clear. To our knowledge, there are no follow-up studies assessing the association between electrocardiographic T-wave peak to T-wave end interval (TPE) and SCD. We assessed the predictive value of electrocardiographic T-wave morphology parameters and TPE for SCD in an adult general population sample. METHODS AND RESULTS A total of 4 T-wave morphology parameters (principal component analysis ratio, T-wave morphology dispersion, total cosine R-to-T, T-wave residuum) as well as TPE were measured from digital standard 12-lead ECGs in 5618 adults (46% men; mean age 50.9±12.5 years) participating in the Finnish population-based Health 2000 Study. After a mean follow-up time of 7.7±1.4 years, 72 SCDs had occurred. In univariable analyses, all T-wave morphology parameters were associated with an increased SCD risk. In multivariable Cox models, T-wave morphology dispersion and total cosine R-to-T remained as predictors of SCD, with T-wave morphology dispersion showing the highest SCD risk (hazard ratio of 1.4 [95% confidence interval 1.1-1.7, P=0.001] per 1 SD increase in the loge T-wave morphology dispersion). In contrast, TPE was not associated with SCD in univariable or multivariable analyses. CONCLUSIONS Electrocardiographic T-wave morphology parameters describing the 3-dimensional shape of the T-wave stratify SCD risk in the general population, but we did not find an association between TPE and SCD.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Effect of Iron Replacement Therapy on Electrocardiographic Consequences in Pediatric Patients

Background Sudden cardiac death is an important problem, because the patients have no opportunity to receive medical service. Recently some electrocardiogram (ECG) parameters are used for predicting arrhythmias, including P wave duration for predicting atrial arrhythmias and corrected QT and T wave peak to end interval (Tp-e), for predicting ventricular arrhythmi...

متن کامل

Electrocardiographic indexes of arrhythmic risk in polycystic ovary syndrome.

Akdag et al1 by investigating several P-wave parameters and the QT interval have recently showed an increased P wave dispersion (PD) and QT dispersion (QTd) in patients affected by polycystic ovary syndrome (PCOS). As acknowledged by the Authors, this population exhibits a high prevalence of cardiac and stroke events and interestingly it shows many risk factors in common with atrial fibrillatio...

متن کامل

Electrocardiographic Parameters of Ventricular Repolarization – Modifiers and the Prognostic Value

Normal electric activity of the heart consists of repeated cardiomyocyte depolarizations and repolarizations. Repolarization of the ventricular action potential is dependent on both inward and outward ion fluxes across cell membranes. Repolarization abnormalities may predispose to ventricular arrhythmias, and several factors may modify repolarization-related arrhythmia vulnerability. Ventricula...

متن کامل

T-wave Alternans Dependency on T-wave Amplitude in Exercise Electrocardiographic Recordings

T-wave alternans (TWA), an electrophysiologic phenomenon which manifests as an everyother-beat alternation of the electrocardiographic (ECG) T-wave amplitude or shape, is generally associated to malignant ventricular arrhythmias and sudden cardiac death. TWA is usually identified with no adjustment for T-wave amplitude. However, a possible dependency of TWA on T-wave amplitude has been recently...

متن کامل

Electrocardiographic parameters of Markhoz goat using base apex lead and six standard limb leads

Electrocardiographic study of 50 healthy Markhoz goats ranging from less than 1 to more than 3 years inage was carried out. The heart rate varied from 99 to 123 beats/min with a mean of 110 beats/min. There wasa significant difference between the heart rate of goats in 3 age groups (PT waves and QT interval in base apex lead, QRS wave in lead I, P-R and PQ interval in aVF lead were higherand du...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Circulation. Arrhythmia and electrophysiology

دوره 6 4  شماره 

صفحات  -

تاریخ انتشار 2013