A diagnostic neutral beam system for the MST reversed-field pinch

نویسندگان

  • G. F. Abdrashitov
  • V. I. Davydenko
  • P. P. Deichuli
  • G. Fiksel
  • A. A. Ivanov
  • S. A. Korepanov
  • S. V. Murakhtin
  • G. I. Shulzhenko
چکیده

A diagnostic neutral beam system has been developed for the Madison symmetric torus ~MST! reversed-field pinch. The system is primarily used: ~1! for measurement of the majority ion equilibrium and fluctuating velocity and temperature by Rutherford scattering ~RS!; ~2! for measurement of the impurity ion velocity and temperature, both equilibrium and fluctuating, by charge-exchange recombination spectroscopy ~CHERS!; and ~3! for magnetic field measurement via motional Stark effect ~MSE!. The system consists of two neutral beam injectors, and two neutral particle analyzers. One injector creates a 20 keV, 4 A helium beam for RS. The energy spectra of the helium beam atoms scattered from the plasma ions is measured with two 12-channel, 45° electrostatic energy analyzers equipped with a hydrogen stripping cell. A second injector creates a 30 keV, 4 A hydrogen beam, which is used for the CHERS and MSE diagnostics. In each injector ions are extracted from a plasma created by an arc discharge source and, after acceleration and focusing, neutralized in a gaseous target. A low ion perpendicular temperature at the plasma emission surface, achieved via plasma expansion cooling, results in a low ~0.016 rad! intrinsic beam divergence. A hallmark of the beam design is the focusing ion optical system that consists of four multiaperture spherically curved electrodes. The geometric focusing, together with a low intrinsic beam divergence, provides a small beam size—5 cm in diameter-on the MST axis and a high neutral current density ~0.4 equivalent A/cm!. A beam injector is compact in size—30 cm in diameter and 70 cm in length—and weighs about 70 kg. In this article we present details of the beam and analyzer designs and first results of their tests on the MST. © 2001 American Institute of Physics. @DOI: 10.1063/1.1318249#

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Calibration of an advanced neutral particle analyzer for the Madison Symmetric Torus reversed-field pinch.

A new E∥B neutral particle analyzer, which has recently been installed on Madison Symmetric Torus (MST) reversed-field pinch (RFP), has now been calibrated, allowing the measurement of the fast ion density and energy distribution. This diagnostic, dubbed the advanced neutral particle analyzer (ANPA), can simultaneously produce time resolved measurements of the efflux of both hydrogen and deuter...

متن کامل

Advances in neutral-beam-based diagnostics on the Madison Symmetric Torus reversed-field pinch „invited..

Innovative charge-exchange recombination spectroscopy !CHERS", motional Stark effect !MSE", and Rutherford scattering diagnostics are now in operation on the Madison Symmetric Torus !MST" reversed-field pinch !RFP". The CHERS diagnostic measures impurity ion flow and temperature, localized to 2 cm with high time resolution !#100 kHz". A spectral MSE diagnostic has been in use for five years, me...

متن کامل

Density fluctuation measurements by far-forward collective scattering in the MST reversed-field pinch.

The multichannel polarimeter-interferometer system on the MST reversed-field pinch can be utilized to measure far-forward collective scattering from electron density fluctuations. The collective scattering system has 11 viewing chords with ∼8 cm spacing. The source is a 432 μm (694 GHz) far infrared laser and the scattered power is measured using a heterodyne detection scheme. Collective scatte...

متن کامل

Confinement of High Energy and High Temperature Ions in the MST Reversed Field Pinch

Confinement of both high energy and high temperature ions has been investigated in the Madison Symmetric Torus (MST) Reversed Field Pinch (RFP), both in standard plasmas with magnetic stochasticity, and improved confinement plasmas in which stochasticity is reduced. We find that (1) energetic ions (produced by neutral beam injection) are very well-confined in the standard RFP plasma despite the...

متن کامل

Time-resolved ion energy distribution measurements using an advanced neutral particle analyzer on the MST reversed-field pinch.

An advanced neutral particle analyzer (ANPA) capable of simultaneously measuring hydrogen and deuterium ions of energies up to 45 keV has recently been developed for use on the Madison Symmetric Torus. The charge-to-mass separation allows for separate analysis of bulk deuterium ions and hydrogen ions injected with a 1 MW, 25 keV neutral beam. Orientation of the ANPA allows sampling of different...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2000