Biomechanical Analysis of Fusion Segment Rigidity Upon Stress at Both the Fusion and Adjacent Segments: A Comparison between Unilateral and Bilateral Pedicle Screw Fixation

نویسندگان

  • Ho-Joong Kim
  • Kyoung-Tak Kang
  • Bong-Soon Chang
  • Choon-Ki Lee
  • Jang-Woo Kim
  • Jin S. Yeom
چکیده

PURPOSE The purpose of this study was to investigate the effects of unilateral pedicle screw fixation on the fusion segment and the superior adjacent segment after one segment lumbar fusion using validated finite element models. MATERIALS AND METHODS Four L3-4 fusion models were simulated according to the extent of decompression and the method of pedicle screws fixation in L3-4 lumbar fusion. These models included hemi-laminectomy with bilateral pedicle screw fixation in the L3-4 segment (BF-HL model), total laminectomy with bilateral pedicle screw fixation (BF-TL model), hemi-laminectomy with unilateral pedicle screw fixation (UF-HL model), and total laminectomy with unilateral pedicle screw fixation (UF-TL model). In each scenario, intradiscal pressures, annulus stress, and range of motion at the L2-3 and L3-4 segments were analyzed under flexion, extension, lateral bending, and torsional moments. RESULTS Under four pure moments, the unilateral fixation leads to a reduction in increment of range of motion at the adjacent segment, but larger motions were noted at the fusion segment (L3-4) in the unilateral fixation (UF-HL and UF-TL) models when compared to bilateral fixation. The maximal von Mises stress showed similar patterns to range of motion at both superior adjacent L2-3 segments and fusion segment. CONCLUSION The current study suggests that unilateral pedicle screw fixation seems to be unable to afford sufficient biomechanical stability in case of bilateral total laminectomy. Conversely, in the case of hemi-laminectomy, unilateral fixation could be an alternative option, which also has potential benefit to reduce the stress of the adjacent segment.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of lumbar interbody fusion performed with unilateral or bilateral pedicle screw.

Currently, bilateral pedicle screw fixation is the standard of instrumentation, providing rigid fixation and an increased fusion rate. However, due to the excessive rigidity of the system, this instrumentation has been suspected to cause degeneration of adjacent segments. Alternatively, less rigid unilateral pedicle fixation is considered to be as effective as bilateral constructs. Few studies ...

متن کامل

Biomechanical comparison of unilateral semi-rigid and dynamic stabilization on ovine vertebrae.

Using the unilateral pedicle screw fixation was thought to decrease the stiffness of the fixed segments. Various prospective, randomized studies were performed to determine whether unilateral pedicle screw fixation provides the necessities of bilateral fixation in one- or two-segment lumbar spinal fusion. In this study, four different unilateral pedicle screw fixation systems were evaluated to ...

متن کامل

Biomechanical Analysis of the Proximal Adjacent Segment after Multilevel Instrumentation of the Thoracic Spine: Do Hooks Ease the Transition?

Study Design Biomechanical cadaveric study. Objective Clinical studies indicate that using less-rigid fixation techniques in place of the standard all-pedicle screw construct when correcting for scoliosis may reduce the incidence of proximal junctional kyphosis and improve patient outcomes. The purpose of this study is to investigate whether there is a biomechanical advantage to using supralami...

متن کامل

Use of unilateral screw-stick and cage bone graft fusion for the treatment of lumbar disc herniation

Previous traditional surgery is simple removal of nucleus pulposus, but the study of Eie et al. shows high recurrence rate of lumbago and herniation after such surgery, 3 therefore, fusion internal fixation of interbody fusion cage combined with bilateral pedicle internal fixation system is often used for treatment at present, so that three-dimensional fixation can be achieved at fused lumbar s...

متن کامل

Finite Element Analysis of a New Pedicle Screw-Plate System for Minimally Invasive Transforaminal Lumbar Interbody Fusion

PURPOSE Minimally invasive transforaminal lumbar interbody fusion (MI-TLIF) is increasingly popular for the surgical treatment of degenerative lumbar disc diseases. The constructs intended for segmental stability are varied in MI-TLIF. We adopted finite element (FE) analysis to compare the stability after different construct fixations using interbody cage with posterior pedicle screw-rod or ped...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 55  شماره 

صفحات  -

تاریخ انتشار 2014