[Influence of shear stress on in-stent restenosis: in vivo study using 3D reconstruction and computational fluid dynamics].

نویسندگان

  • Marcelo Sanmartín
  • Javier Goicolea
  • Carlos García
  • Javier García
  • Antonio Crespo
  • Javier Rodríguez
  • José M Goicolea
چکیده

INTRODUCTION AND OBJECTIVES Local factors may influence neointimal proliferation following conventional stent implantation. In this study, the relationship between wall shear stress and luminal loss after coronary stenting was assessed using a combination of angiography, intravascular ultrasound, and computational fluid dynamics. PATIENTS AND METHOD Seven patients with de novo right coronary lesions treated with conventional (i.e., bare metal) stents were included. Realistic three-dimensional geometric reconstructions were generated offline from angiographic and intravascular ultrasound data both immediately after stenting and at 6-month follow-up. A finite-volume model was used to calculate local wall shear stress within the stent and 4 mm proximally and distally to the stent. The mean coronary ostium entry flow velocity was assumed to be 25 cm/s in all cases. RESULTS The mean neointimal thickness was 0.29 (0.21) mm. In five cases, weak negative correlations between wall shear stress and neointimal thickness were found: maximum r value = -0.34, minimum r value = -0.11 (P < .001). The neointimal thickness in segments in which the level of wall shear stress was in the lowest quartile was greater than that in segments in which it was in highest quartile, at 0.34 (0.21) mm and 0.27 (0.24) mm (P < .001) for quartiles 1 and 4, respectively. CONCLUSIONS Low wall shear stress after stenting favors neointimal proliferation both within the stent and at the stent's edges.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Microfocal X-ray computed tomography post-processing operations for optimizing reconstruction volumes of stented arteries during 3D computational fluid dynamics modeling

Restenosis caused by neointimal hyperplasia (NH) remains an important clinical problem after stent implantation. Restenosis varies with stent geometry, and idealized computational fluid dynamics (CFD) models have indicated that geometric properties of the implanted stent may differentially influence NH. However, 3D studies capturing the in vivo flow domain within stented vessels have not been c...

متن کامل

Axial stent strut angle influences wall shear stress after stent implantation: analysis using 3D computational fluid dynamics models of stent foreshortening

INTRODUCTION The success of vascular stents in the restoration of blood flow is limited by restenosis. Recent data generated from computational fluid dynamics (CFD) models suggest that the vascular geometry created by an implanted stent causes local alterations in wall shear stress (WSS) that are associated with neointimal hyperplasia (NH). Foreshortening is a potential limitation of stent desi...

متن کامل

Comparison of Stent Designs using Computational Fluid Dynamics

Coronary artery disease (CAD) is one of the leading causes of death in the developed world. CAD occurs due to the build up of plaque in the coronary arteries which supply fresh blood to the constantly active heart muscle. Several methods exist to alleviate CAD such as coronary artery bypass grafting, balloon angioplasty and coronary stenting. A coronary stent is a small tubular prosthesis which...

متن کامل

Relationship between neointimal thickness and shear stress after Wallstent implantation in human coronary arteries.

BACKGROUND In-stent restenosis by excessive intimal hyperplasia reduces the long-term clinical efficacy of coronary stents. Because shear stress (SS) is related to plaque growth in atherosclerosis, we investigated whether variations in SS distribution are related to variations in neointima formation. METHODS AND RESULTS In 14 patients, at 6-month follow-up after coronary Wallstent implantatio...

متن کامل

Shear Stress and Wall Strain Distribution in Human Coronary Arteries In-vivo

strain measurement (right). INTRODUCTION Blood flow induced wall shear stress (SS) plays an important role in the (patho)physiology of the vascular wall [1]. Recently tools became available to study the 3-dimensional SS distribution in the coronary arteries relative to local wall morphology in-vivo [2]. In addition, local strain distribution in the wall can be measured with an ultrasound-based ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Revista espanola de cardiologia

دوره 59 1  شماره 

صفحات  -

تاریخ انتشار 2006