Grading Carotid Intrastent Restenosis

نویسنده

  • Francesca Iacoponi
چکیده

Background and Purpose—The accuracy of carotid ultrasound has not been well established in predicting intrastent restenosis (ISR) after carotid artery stenting (CAS). The aim of this study is to determine different degrees of ISR using ultrasound velocity criteria compared to percentage of stenosis at angiography. Methods—This is a 6-year prospective study. After CAS procedure, each patient underwent angiography for measuring ISR (NASCET method) which was compared to peak systolic velocity (PSV), end diastolic velocity (EDV), and the ratio between PSV of internal carotid artery and common carotid artery (ICA/CCA). This was done within 48 hours, thus creating a baseline value. Ultrasound (US) examination was performed at day 30, at 3, 6, 9, and 12 months, and then yearly. Patients with an increase in PSV greater than 3 times the baseline value or in presence of PSV 200 cm/s underwent angiography. Results—814 CAS procedures, 6427 US examinations, and 1123 angiographies were performed. ISR 70% and ISR 50% was detected, respectively, in 22 patients and in 73 patients. We defined velocity criteria for grading carotid ISR: PSV 104 cm/s, if 30% stenosis; PSV:105 to 174 cm/s if 30% to 50% stenosis; PSV:175 to 299 cm/s if a 50% to 70% stenosis; PSV 300 cm/s, EDV 140 cm/s, and ICA/CCA 3.8 if a 70% stenosis. Receiver operator characteristic (ROC) curves for ISR 70% were, respectively, for PSV, EDV, and ICA/CCA: 0.99, 0.98, and 0.99. Conclusions—US grading of carotid ISR can guarantee a correct follow-up after CAS if new customized velocity criteria are validated by skilled operators using a specific protocol of follow-up in a certified laboratory. (Stroke. 2008;39:11891196.)

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Grading carotid intrastent restenosis: a 6-year follow-up study.

BACKGROUND AND PURPOSE The accuracy of carotid ultrasound has not been well established in predicting intrastent restenosis (ISR) after carotid artery stenting (CAS). The aim of this study is to determine different degrees of ISR using ultrasound velocity criteria compared to percentage of stenosis at angiography. METHODS This is a 6-year prospective study. After CAS procedure, each patient u...

متن کامل

Cutting balloon angioplasty for intrastent restenosis treatment.

We describe here two patients with angiographic diagnosis of intrastent restenosis and regional myocardial ischemia. One stent restenosis was located in a native coronary artery and the other in a vein graft. Both were treated with cutting balloon angioplasty (CBA), inflated at low pressures. Angiographic success was obtained and both patients were discharged in the day after the procedure. Cut...

متن کامل

Acute hemifacial ischemia as a late complication of carotid stenting

Concerns about carotid artery stenting (CAS) center primarily on procedural complications like acute occlusion, stroke, and long-term intrastent restenosis. External carotid artery (ECA) thrombosis is observed during CAS follow-up, but it often remains asymptomatic or, at worst, results in jaw claudication. We report here a case of late occlusion of the ECA after CAS with symptoms of acute homo...

متن کامل

Edge Restenosis After Implantation of High Activity P Radioactive b-Emitting Stents

Background—A high restenosis rate has been reported at the edges (“edge restenosis”) of P radioactive stents with an initial activity level of 3 to 12 mCi. This edge effect might be due to balloon injury and to a low dose of radiation at the stent margins. The aim of this study was to evaluate whether the implantation of P radioactive stents with a higher activity level (12 to 21 mCi) combined ...

متن کامل

Impact of peri-stent remodeling on restenosis: a volumetric intravascular ultrasound study.

BACKGROUND Vessel remodeling is an important mechanism of late lumen loss after nonstent coronary interventions. However, its impact on in-stent restenosis has not been systematically investigated. METHODS AND RESULTS Serial volumetric intravascular ultrasound analyses (poststent and follow-up) were performed in 55 lesions treated with a balloon-expandable stent (ACS MultiLink) using standard...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2008