Left ventricular mechanical efficiency in man with heart disease.
نویسندگان
چکیده
Thirty-eight adults with valvular and/or myocardial disease had heart catheterization with coronary blood flow and myocardial O2 consumption (MVO2) per 100 g measured by the nitrous oxide washout technique. Quantitative biplane angiocardiography was performed to assess left ventricular volume, mass, ejection fraction and work. Left ventricular efficiency was calculated from work, MVO2/100 g and mass. Efficiency ranged from 4 to 40% and was normal in some patients with severe ventricular pressure-volume work overloads. Total left ventricular MVO2 ranged up to 461 ml/min. Neither total MVO2 nor MVO2/100 g was significantly related to ventricular work, ejection fraction, or tension-time index. These data suggest 1) a relationship between left ventricular efficiency and myocardial function in chronic valvular or myocardial disease, 2) that efficiency may be normal in hypertrophied ventricles, and 3) that chronic increases in resting ventricular metabolic requirements are met by hypertrophy rather than by increased MVO2/100 g.
منابع مشابه
Improvement of Left Ventricular Assist Device (LVAD) in Artificial Heart Using Particle Swarm Optimization
In this approach, the Left ventricular assist pump for patients with left ventricular failure isused. The failure of the left ventricle is the most common heart disease during these days. Inthis article, a State feedback controller method is used to optimize the efficiency of a samplingpump current. Particle Swarm Algorithm, which is a set of rules to update the position andvelocity, is applied...
متن کاملThe Correlation between Left and Right Ventricular Ejection Fractions in Patients with Ischemic Heart Disease, Documented by Cardiac Magnetic Resonance Imaging
Introduction: The correlation between right and left ventricular ejection fractions (RVEF and LVEF, respectively) has been studied in only a small number of patients with a marked decrease in RVEF and LVEF. The aim of the present study was to compare LVEF and RVEF in patients with ischemic heart disease. RVEF and LVEF were measured by Cardiovascular Magnetic Resonance (CMR) imaging. Materials a...
متن کاملDesign an Equivalent Left Ventricular Assist Device for Medical Equipment Labs
LVAD is a mechanical pump supporting a weak heart function and blood flow. Sometimes, the heart may not recover fast enough to take over the pumping action immediately after surgery, in such patients a temporary support device has been employed to maintain the pumping action until the patient’s own heart recovers. This device can be considered as a temporary alternative before the process of ar...
متن کاملImpact of Phase Analysis of Gated SPECT to Assessment of Left Ventricular Mechanical Dyssynchrony in Diabetic Patients with Normal MPI
Objective: Diabetes mellitus is an important cause of heart failure deployment of left ventricular mechanical dyssynchrony. Nuclear cardiology phase analysis is an accurate, repeatable and reproducible modality for measurement LV dyssynchrony .The aim of study was assessment of phase analysis parameter including Standard deviation (SD) and band width (BW) in diabetic patient with normal MPI com...
متن کاملCan chronotropic incompetence predict life-threatening ventricular arrhythmias in patients with stable ischemic heart disease?
Background: Chronotropic incompetence has prognostic value of all-cause and cardiovascular mortality in both patients with asymptomatic and symptomatic ischemic heart disease (IHD), regardless of traditional risk factors. The aim of this study was to investigate the relationship between chronotropic response during exercise test and the development of ventricular arrhythmias. Methods: 153 pati...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Circulation
دوره 55 4 شماره
صفحات -
تاریخ انتشار 1977