[Reproducibility of measurements of left ventricular function with gated myocardial perfusion SPECT and comparison with blood pool radionuclide ventriculography].
نویسندگان
چکیده
INTRODUCTION AND OBJECTIVE This study was designed to evaluate the reproducibility of ejection fraction (EF) and ventricular volume measurements obtained with single photon emission computed tomography (gated-SPECT), and to assess the correlation between EF values obtained with this method and blood pool planar radionuclide ventriculography. PATIENTS AND METHOD A total of 55 patients were included (37 men, mean age 61.3 years) upon referral to two nuclear cardiology units for diagnosis (50%) or follow-up of known coronary artery disease. In a standard 2-day protocol, patients received a dose of [99mTc]tetrofosmin (800 MBq) at stress and at rest. Two resting gated-SPECT studies were performed. QGS software was used to obtain left ventricular EF, end-diastolic volume (EDV) and end-systolic volume (ESV). Forty-nine patients agreed to undergo blood pool ventriculography on the third day. RESULTS Interobserver variability was 0.5 (2.6)% (r=0.99) for EF, 1.9 (10.7) mL for EDV (r=0.98) and 0.5 (5.4) mL for ESV (r=0.99). Interassay variability was 2 (5.1)% (r=0.94) for EF, 4.5 (8.6) mL for EDV (r=0.99) and 3.4 (6.6) mL for ESV (r=0.99). The correlation between gated-SPECT EF and blood pool EF was suboptimal (r=0.75, 95%CI, 0.59-0.85). CONCLUSIONS There was excellent interobserver and interassay reproducibility for left ventricular functional parameters measured with gated-SPECT and QGS software, and this method can be used for serial evaluations of ventricular function. Although the correlation between values obtained with gated-SPECT and blood pool ventriculography was acceptable, the differences show that the two techniques cannot be considered equivalent.
منابع مشابه
Diastolic left ventricular functional indices: Comparison between gated myocardial perfusion SPECT and echocardiography
Introduction: Many patients have only diastolic dysfunction without any abnormality in systolic function. We compared cardiac diastolic parameters obtained by gated myocardial perfusion SPECT (Gated SPECT) with those evaluated by echocardiography. Methods: Forty-nine patients (aged 37-85 years, 19 males and 30 women) underwent Gated SPECT and echocardiogr...
متن کاملDipyridamole stress and rest gated 99mTc-sestamibi myocardial perfusion SPECT: left ventricular function indices and myocardial perfusion findings
Introduction: We investigated the difference in left ventricular ejection fraction (LVEF) and end-systolic volume(ESV) measured by gated myocardial perfusion SPECT (GSPECT) in the post-dipyridamole stress and rest periods, and compared the results with the perfusion patterns found in the conventional non-gated tomograms. Methods: 297 consecutive patients were studie...
متن کاملThe role of oral dipyridamole stress gated SPECT in assessing the response of the left ventricle to stress: Re-evaluation of an old method
Introduction: We aimed to assess whether the vasodilator effect of oral dipyridamole on the left ventricular systolic function in patients with suspected CAD is different from that of intravenous (IV) dipyridamole using Tc-99m MIBI myocardial perfusion gated SPECT. Methods: Eighty-nine patients (17 M / 72 W; 61 ± 10 years) were enrolled in this study. The patients underwent a dipyridamole stre...
متن کاملNormal values of left ventricular functional indices in gated 99mTc-MIBI myocardial perfusion SPECT
Introduction: Although left ventricular(LV) function parameters measured by gated myocardial perfusion SPECT (GSPECT) have been validated, experimental data have revealed that the calculated the LV function parameters using GSPECT are affected by patient populations as well as particular acquisition and processing conditions. We tried to determine the normal values ...
متن کامل[Assessment of biventricular function using gated blood pool SPECT with QBS software: comparison with planar radionuclide ventriculography].
UNLABELLED Quantitative blood pool SPECT (QBS) is a new application for the quantitative assessment of biventricular function from gated blood pool SPECT (TMUGA). In this study, we compared biventricular function between planar radionuclide ventriculography and TMUGA. The reproducibility of measuring biventricular ejection fraction with QBS was also evaluated. MATERIALS AND METHODS Thirty-fiv...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Revista espanola de cardiologia
دوره 57 10 شماره
صفحات -
تاریخ انتشار 2004