Absolute Spectrophotometry of Vega from the Far - Uv to the Ir
نویسندگان
چکیده
The Space Telescope Imaging Spectrograph has measured the absolute flux for Vega from 0.17–1.01 µm on the HST White Dwarf flux scale. These data are saturated by up to a factor of 80 overexposure but retain linearity to a precision of 0.2%, because the charge bleeds along the columns and is recovered during readout of the CCD. The S/N per pixel exceeds 1000, and the resolution R is about 500. A V magnitude of 0.026±0.008 is established for Vega; and the absolute flux level is 3.46 × 10 −9 erg cm −2 s −1 at 5556Å. In the regions of Balmer and Paschen lines, the STIS equivalent widths differ from the pioneering work of Hayes in 1985 but do agree with predictions of a Kurucz model atmosphere, so that the STIS flux distribution is preferred to that of Hayes. Over the full wavelength range, the model atmosphere calculation shows excellent agreement with the STIS flux distribution and is used to extrapolate predicted fluxes into the IR region. However, the IR fluxes are 2% low with respect to the standard Vega model of Cohen. IUE data provide the extension of the measured STIS flux distribution from 0.17 down to 0.12 µm. The STIS relative flux calibration is based on model atmosphere calculations of pure hydrogen WDs, while the Hayes flux calibration is based on the physics of laboratory lamps and black body ovens. The agreement to 1% of these two independent methods for determining the relative stellar flux distributions suggests that both methods may be correct from 0.5–0.8 µm and adds confidence to claims that the fluxes relative to 5500Å are determined to better than 4% by the pure hydrogen WD models from 0.12 to 3 µm.
منابع مشابه
The Future of Photometric, Spectrophotometric and Polarimetric Standardization
Free of any atmospheric contamination, the Hubble Space Telescope provides the best available spectrophotometry from the far-UV to the near-IR for stars as faint as V ∼ 16. The HST CALSPEC standard star network is based on three standard candles: the hot, pure hydrogen white dwarf (WD) stars G191B2B, GD153, and GD71, which have Hubeny NLTE model flux calculations that require the atomic physics...
متن کاملSpectrophotometric Standards from the Far-uv to the Near- Ir on the White Dwarf Flux Scale
The second generation instruments to be installed in 1997 on the Hubble Space Telescope (HST) require spectrophotometric standard stars for ux calibrations to 1.1 m for the imaging spectrograph (STIS) and to 2.5 m for the infrared camera (NICMOS). Calculated model atmosphere ux distributions from 0.1 to 3 m for four pure hydrogen white dwarfs provide the fundamental basis for a new set of spect...
متن کاملThe Absolute Flux Distribution of Lds749b
Observations from the Space Telescope Imaging Spectrograph define the flux of the DBQ4 star LDS749B from 0.12–1.0 μmwith an uncertainty of∼1% relative to the three pure hydrogen WD primary HST standards. With Teff = 13575 K, log g = 8.05, and a trace of carbon at <1×10 of solar, a He model atmosphere fits the measured STIS fluxes within the observational noise, except in a few spectral lines wi...
متن کاملGabapentin Determination in Human Plasma and Capsule by Coupling of Solid Phase Extraction, Derivatization Reaction, and UV-Vis Spectrophotometry
Gabapentin is an anticonvulsant widely used in the treatment of epilepsy. No peculiar chromophore is available on the gabapentin moiety for direct analysis by absorption spectrophotometry. A sensitive spectrophotometric method for the determination of gabapentin in bulk, pharmaceutical formulations and human plasma has been developed. In this method, gabapentin directly derivatized with vanilli...
متن کاملDetermination of Sulfamethoxazole and Trimethoprim in Pharmaceuticals by Visible and UV Spectrophotometry
A method for the simultaneous determination of sulfamethoxazole (SMX) and trimethoprim (TMP), based on a direct determination of SMX after diazotization and coupling with 2-naphthol by visible spectrophotometry and an indirect determination of TMP in the UV region by difference was developed. By the suggested procedure, it was possible to analyze SMX and TMP in pharmaceutical preparations witho...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2004