Difficulty in advancing a tracheal tube over a fibreoptic bronchoscope: incidence, causes and solutions.

نویسندگان

  • A Higgs
  • L Parker
چکیده

Fibreoptic tracheal intubation is a useful technique in patients whose tracheas are dif®cult to intubate. 69 However, there are two major dif®culties with this technique. The ®rst is location of the glottis and insertion of a ®brescope into the trachea. Induction of general anaesthesia (with or without neuromuscular block) causes the soft palate, tongue and epiglottis to approximate to the posterior pharyngeal wall, and thus little air space is left in the oropharynx for manoeuvring the tip of the ®brescope to locate the glottis. The second dif®culty is insertion of a tube over the ®brescope into the trachea. There have been reports of failed tracheal intubation despite successful insertion of a ®brescope into the trachea. 89 To solve the ®rst dif®culty, several manoeuvres (such as thrusting the jaw forward, extension of the head, or traction of the tongue) have been proposed, and airway intubators (such as the Berman, Ovassapian and Williams) have been developed. In addition, there have been comprehensive articles discussing effective ways of teaching ®brescopy. 66 69 85 In contrast, there have been no textbooks or reviews which comprehensively deal with the second dif®culty, of advancing a tracheal tube over a ®brescope. Therefore, the main aim of this review article is to analyse the incidence of, causes of and possible solution to, the dif®culty in advancing a tube over a ®brescope into the trachea.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Randomized, controlled trial of the double setup tracheal tube during fibreoptic orotracheal intubation under general anaesthesia.

BACKGROUND Impingement of the tracheal tube (ETT) on upper airway structures during railroading over the fibreoptic bronchoscope (FOB) occurs commonly. Potential complications of impingement include prolonged intubation time, leading to arterial desaturation, failed intubation and laryngeal trauma. The objective of this randomized, controlled trial was to assess the effect of the double setup E...

متن کامل

Rapidity and accuracy of tracheal intubation in a mannequin: comparison of the fibreoptic with the Bullard laryngoscope.

Successful tracheal intubation with the flexible fibreoptic bronchoscope requires a certain amount of skill which is acquired by practice. It has been suggested that the new Bullard laryngoscope may be mastered more easily. To determine if learning was superior with a flexible fibreoptic or the Bullard device, the ease of tracheal intubation with both devices was compared by first-year anaesthe...

متن کامل

Repeated Tracheostomy Tube Cuff Rupture Due to Tracheobronchopathia Osteochondroplastica: A Case Report

Introduction: Tracheobronchopathia osteochondroplastica (TPO) is a rare benign disorder of the lower part of the trachea and the upper part of the main bronchi.   Case Report: A case of tracheobronchopathia osteochondroplastica (TPO) diagnosed at the time of intubation in an intensive care unit due to difficulty when advancing the endotracheal tube beyond the vocal cords, is reported. A problem...

متن کامل

GlideScope® vs flexible fibreoptic scope for elective intubation in obese patients.

We hypothesised that in obese patients, tracheal intubation with the GlideScope® would be advantageous compared with flexible fibreoptic intubation. Seventy-five anaesthetised obese patients were randomly assigned to oral intubation by either GlideScope or flexible fibreoptic bronchoscope. We compared the two devices for time to intubate (p = 0.19), difficulty of intubation (p = 0.58), successf...

متن کامل

The intubating laryngeal mask airway in failed fibreoptic intubation.

PURPOSE Prediction of difficult tracheal intubation is not always reliable and management with fibreoptic intubation is not always successful. We describe two cases in which blind intubation through the intubating laryngeal mask airway (ILMA FasTrach) succeeded after fibreoptic intubation failed. CLINICAL FEATURES The first patient, a 50 yr old man, was scheduled for elective craniotomy for i...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • British journal of anaesthesia

دوره 93 6  شماره 

صفحات  -

تاریخ انتشار 2004