Arterial microsphere concentrations in cats are not affected by changes in hematocrit.

نویسندگان

  • D S DeWitt
  • D S Prough
  • D D Deal
  • H M Hoen
چکیده

BACKGROUND AND PURPOSE Acute anemia may lead to erroneously low arterial reference sample concentrations of radioactive microspheres, depending on the sampling rate and the size of the artery from which the reference samples are withdrawn. Because this error would lead to falsely high cerebral blood flow values in studies involving hemodilution caused by hemorrhage and fluid resuscitation, we studied the effects of hematocrit, withdrawal rate, and vessel location and size on arterial microsphere concentrations in anesthetized adult cats. METHODS Cats were anesthetized with ketamine, isoflurane, and nitrous oxide; both brachial arteries were cannulated with polyethylene tubing, as was the abdominal aorta through the femoral artery. Sequential left atrial microsphere injections were made using several doses of each of five isotopes. The rate of reference sample withdrawal from the three sampling catheters was randomized to 1.03 mL.min-1 or 2.06 mL.min-1. We analyzed the ratio of the number of microspheres in paired reference samples using the factors hematocrit, rate of withdrawal, and site. A ratio less than 1 indicates an underestimation of arterial microsphere concentration, which would lead to erroneously high cerebral blood flow values. The procedure was repeated after isovolemic hemodilution with 10% hetastarch to hemoglobin levels approximating 85%, 70%, 55%, and 40% of baseline. RESULTS No significant effects of hematocrit on ratios of microsphere concentrations existed at any withdrawal rate or site. Ratios of microsphere concentrations in reference samples withdrawn slowly (1.03 mL.min-1) from the aorta and ratios of microsphere concentrations withdrawn either rapidly (2.06 mL.min-1) or slowly from the brachial arteries were significantly (P < .001) less than 1. CONCLUSIONS Hemodilution did not affect microsphere concentrations in arterial reference samples at any withdrawal site or rate and therefore does not affect the accuracy of microsphere blood flow determinations. However, slow withdrawal from a large vessel may underestimate actual microsphere concentrations.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Biocompatibility research of a novel pH sensitive ion exchange resin microsphere

The main objective of this study was to investigate biocompatibility and provide in vivo pharmacological and toxicological evidence for further investigation of the possibility of pH sensitive ion exchange resin microsphere for clinical utilizations. Acute toxicity study and general pharmacological studies were conducted on the pH sensitive ion exchange resin microsphere we prepared. The genera...

متن کامل

Biocompatibility research of a novel pH sensitive ion exchange resin microsphere

The main objective of this study was to investigate biocompatibility and provide in vivo pharmacological and toxicological evidence for further investigation of the possibility of pH sensitive ion exchange resin microsphere for clinical utilizations. Acute toxicity study and general pharmacological studies were conducted on the pH sensitive ion exchange resin microsphere we prepared. The genera...

متن کامل

Blood flow after retinal ischemia in cats.

PURPOSE To determine the changes in blood flow in the cat retina after 1 hour of ischemia. METHODS Blood flow in the retina and choroid of adult cats anesthetized with chloralose, acepromazine, and halothane was measured using sequential injections of radioactively labeled microspheres. Ischemia was induced by elevation of intraocular pressure above systolic arterial pressure. Measurements we...

متن کامل

Hematologic, hemostatic, and biochemical effects in cats receiving an oral chondroprotective agent for 30 days.

The objective of this study was to evaluate the effects of a chondroprotective agent on hematologic, hemostatic, and biochemical variables in clinically normal cats when administered at twice the recommended levels for 30 days. Fifteen clinically normal female domestic shorthaired cats were used. Twelve cats were given a chondroprotective agent orally, twice daily for 30 days. Three cats served...

متن کامل

Washout kinetics of red cells and plasma from the spleen.

Radioiodinated (125I) serum albumin was injected inttravenously in cats and allowed to equilibrate in the circulation. Red cell and plasma washout from the isolated spleens were enrom the isolated spleens were then compared during perfusion with oxygenated Ringer solution, the respective concentrations in the outflow being measured by celloscope and scintillation counters. Washout kinetics yiel...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Stroke

دوره 25 9  شماره 

صفحات  -

تاریخ انتشار 1994