Sensitive and rapid HPLC-UV method with back-extraction step for the determination of sildenafil in human plasma.

نویسندگان

  • Hamza Al-Hroub
  • Bayan Alkhawaja
  • Eman Alkhawaja
  • Tawfiq Arafat
چکیده

In this work we provided a selective, sensitive and rapid HPLC-UV method for quantification of sildenafil in human plasma. We have adopted a simple liquid-liquid extraction procedure followed a back-extraction in 5% perchloric acid solution. Chromatographic separation was achieved on a BDS C-18Column (150mm×4.6mm, 5μm) using a mobile phase consisted 63% water, 37% acetonitrile and 0.1% triethylamine (pH 7.7). The analysis was detected at 230nm. The achieved lower limit of quantification was 2.00ng/ml. The method showed linear calibration curve over the range of 2.00-200ng/ml. Intra- and inter day precision (CV%) were less than 6.80 and 5.19%, respectively. Whilst intra- and inter day accuracy% were ranged between (98.3 and 105%) and (99.4 and 103%), respectively. Tests confirmed the stability of sildenafil in plasma at room temperature for 24h, during three freeze-thaw cycles, after 24h in autosampler at 10°C and after 60 days in plasma at -30°C. The recovery of sildenafil was greater than 78.4%. The described simple UV method achieved very low limit of quantification and by using simple and inexpensive extraction procedure, complete separation was obtained within short run time. Having demonstrated the validity and novelty of our method, thus it is applicable for the clinical and pharmacokinetic studies of sildenafil in human volunteers especially in laboratories in countries where cost of modern techniques and instrumentation is prohibitive.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A High-Performance Liquid Chromatographic Assay for the Determination of Losartan in Plasma

A rapid and sensitive HPLC method was developed for determination of losartan in plasma. Losartan was extracted from plasma by a two-step extraction procedure using chloroform as extracting solvent in acidic medium. HPLC analysis was performed on a cyano reversed-phase column using phosphate buffer (pH 4.3), acetonitrile (750:250, v/v) as mobile phase with a flow rate of 0.9 mL/min. Sodium dicl...

متن کامل

Simple High-Performance Liquid Chromatographic Method for Determination of Ciprofloxacin in Human Plasma

A rapid, simple and sensitive high-performance liquid chromatography method was developed for determination of ciprofloxacin in plasma by means of ultraviolet detection. Ofloxacin was used as an internal standard and separation carried on a Novapak C18 column using a mobile phase of 0.01 M phosphate buffer (pH =2.6): methanol (82: 18 v/v). Extraction of drug was performed from plasma by liquid-...

متن کامل

Simple High-Performance Liquid Chromatographic Method for Determination of Ciprofloxacin in Human Plasma

A rapid, simple and sensitive high-performance liquid chromatography method was developed for determination of ciprofloxacin in plasma by means of ultraviolet detection. Ofloxacin was used as an internal standard and separation carried on a Novapak C18 column using a mobile phase of 0.01 M phosphate buffer (pH =2.6): methanol (82: 18 v/v). Extraction of drug was performed from plasma by liquid-...

متن کامل

Rapid High Performance Liquid Chromatographic Determination of Risperidone in Human Plasma

A simple, rapid and sensitive high-performance liquid chromatographic (HPLC) method for the determination of risperidone in human plasma was developed. An HPLC system based on a Nucleosil C8 column (150?4 mm) and a UV detector (?= 280 nm) were used. A mixture of sodium dihydrogen phosphate buffer-acetonitrile (55:45, v/v) adjusted to pH 6.0 at a flow rate of 1.5 ml min-1 was used as mobile phas...

متن کامل

Rapid High Performance Liquid Chromatographic Determination of Risperidone in Human Plasma

A simple, rapid and sensitive high-performance liquid chromatographic (HPLC) method for the determination of risperidone in human plasma was developed. An HPLC system based on a Nucleosil C8 column (150?4 mm) and a UV detector (?= 280 nm) were used. A mixture of sodium dihydrogen phosphate buffer-acetonitrile (55:45, v/v) adjusted to pH 6.0 at a flow rate of 1.5 ml min-1 was used as mobile phas...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of chromatography. B, Analytical technologies in the biomedical and life sciences

دوره 1009-1010  شماره 

صفحات  -

تاریخ انتشار 2016