Cardiac output during exercise by the open circuit acetylene washin method: comparison with direct Fick.
نویسندگان
چکیده
An open-circuit (OpCirc) acetylene uptake cardiac output (QT) method was modified for use during exercise. Two computational techniques were used. OpCirc1 was based on the integrated uptake vs. end-tidal change in acetylene, and OpCirc2 was based on an iterative finite difference modeling method. Six subjects [28-44 yr, peak oxygen consumption (VO(2)) = 120% predicted] performed cycle ergometry exercise to compare QT using OpCirc and direct Fick methods. An incremental protocol was repeated twice, separated by a 10-min rest, and subsequently subjects exercised at 85-90% of their peak work rate. Coefficient of variation of the OpCirc methods and Fick were highest at rest (OpCirc1, 7%, OpCirc2, 12%, Fick, 10%) but were lower at moderate to high exercise intensities (OpCirc1, 3%, OpCirc2, 3%, Fick, 5%). OpCirc1 and OpCirc2 QT correlated highly with Fick QT (R(2) = 0.90 and 0.89, respectively). There were minimal differences between OpCirc1 and OpCirc2 compared with Fick up to moderate-intensity exercise (<70% peak VO(2)); however, both techniques tended to underestimate Fick at >70% peak VO(2). These differences became significant for OpCirc1 only. Part of the differences between Fick and OpCirc methods at the higher exercise intensities are likely related to inhomogeneities in ventilation and perfusion matching (R(2) = 0.36 for Fick - OpCirc1 vs. alveolar-to-arterial oxygen tension difference). In conclusion, both OpCirc methods provided reproducible, reliable measurements of QT during mild to moderate exercise. However, only OpCirc2 appeared to approximate Fick QT at the higher work intensities.
منابع مشابه
Comparison of cardiac output determined by a carbon dioxide-rebreathing and direct Fick method at rest and during exercise.
1. To study the validity of a CO2-rebreathing method at rest and during graded exercise, cardiac output was measured simultaneously on 59 occasions in 16 subjects with normal pulmonary function with the CO2-rebreathing method and the direct Fick method for oxygen. The correlation coefficient between the results of both methods was significantly higher during exercise than at rest. 2. No systema...
متن کاملMeasurement of cardiac output during exercise by open-circuit acetylene uptake.
Noninvasive measurement of cardiac output (QT) is problematic during heavy exercise. We report a new approach that avoids unpleasant rebreathing and resultant changes in alveolar PO(2) or PCO(2) by measuring short-term acetylene (C(2)H(2)) uptake by an open-circuit technique, with application of mass balance for the calculation of QT. The method assumes that alveolar and arterial C(2)H(2) press...
متن کاملA Comparison of the Direct Fick and the Grollman Methods for Determination of the Cardiac Output in Man.
The introduction of the cardiac catheter by Forssman (1) and its later development as a useful physiological instrument by Cournand (2, 3) have made possible the determination of the cardiac output by the direct Fick principle in man (4). Using this method, a number of investigators have reported values of 5.5 to 6.5 liters per minute for the basal cardiac output, which correspond to 3.1 to 3.8...
متن کاملEvaluation of two methods for continuous cardiac output assessment during exercise in chronic heart failure patients.
The purpose of this study was to evaluate the accuracy of two techniques for the continuous assessment of cardiac output in patients with chronic heart failure (CHF): a radial artery pulse contour analysis method that uses an indicator dilution method for calibration (LiDCO) and an impedance cardiography technique (Physioflow), using the Fick method as a reference. Ten male CHF patients (New Yo...
متن کاملDifferences of cardiac output measurements by open-circuit acetylene uptake in pulmonary arterial hypertension and chronic thromboembolic pulmonary hypertension: a cohort study
BACKGROUND As differences in gas exchange between pulmonary arterial hypertension (PAH) and chronic thromboembolic pulmonary hypertension (CTEPH) have been demonstrated, we asked if cardiac output measurements determined by acetylene (C2H2) uptake significantly differed in these diseases when compared to the thermodilution technique. METHOD Single-breath open-circuit C2H2 uptake, thermodiluti...