Cardiac responses to left ventricular pacing in hearts with normal electrical conduction: beneficial effect of improved filling is counteracted by dyssynchrony.

نویسندگان

  • Espen Boe
  • Kristoffer Russell
  • Espen W Remme
  • Ola Gjesdal
  • Otto A Smiseth
  • Helge Skulstad
چکیده

Cardiac resynchronization therapy (CRT) has been proposed in heart failure patients with narrow QRS, but the mechanism of a potential beneficial effect is unknown. The present study investigated the hypothesis that left ventricular (LV) pacing increases LV end-diastolic volume (LVEDV) by allowing the LV to start filling before the right ventricle (RV) during narrow QRS in an experimental model. LV and biventricular pacing were studied in six anesthetized dogs before and after the induction of LV failure. Function was evaluated by pressures and dimensions, and dyssynchrony was evaluated by electromyograms and deformation. In the nonfailing heart, LV pacing gave the LV a head start in filling relative to the RV (P < 0.05) and increased LVEDV (P < 0.05). The response was similar during LV failure when RV diastolic pressure was elevated. The pacing-induced increase in LVEDV was attributed to a rightward shift of the septum (P < 0.01) due to an increased left-to-right transseptal pressure gradient (P < 0.05). LV pacing, however, also induced dyssynchrony (P < 0.05) and therefore reduced LV stroke work (P < 0.05) during baseline, and similar results were seen in failing hearts. Biventricular pacing did not change LVEDV, but systolic function was impaired. This effect was less marked than with LV pacing. In conclusion, pacing of the LV lateral wall increased LVEDV by displacing the septum rightward, suggesting a mechanism for a favorable effect of CRT in narrow QRS. The pacing, however, induced dyssynchrony and therefore reduced LV systolic function. These observations suggest that detrimental effects should be considered when applying CRT in patients with narrow QRS.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Diminished left ventricular dyssynchrony and impact of resynchronization in failing hearts with right versus left bundle branch block.

OBJECTIVES We compared mechanical dyssynchrony and the impact of cardiac resynchronization therapy (CRT) in failing hearts with a pure right (RBBB) versus left bundle branch block (LBBB). BACKGROUND Cardiac resynchronization therapy is effective for treating failing hearts with conduction delay and discoordinate contraction. Most data pertain to LBBB delays. With RBBB, the lateral wall contra...

متن کامل

Coupled pacing improves left ventricular function during simulated atrial fibrillation without mechanical dyssynchrony.

AIMS Electrical stimulation [coupled pacing (CP)] applied near the end of the T-wave is able to create a retrograde activation of the atrioventricular (AV) node in turn to prevent rapid ventricular conduction during atrial fibrillation (AF). The impact of this pacing modality associated with cardiac resynchronization therapy (CRT) has been evaluated in the present experimental study. METHODS ...

متن کامل

Interplay of electrical wavefronts as determinant of the response to cardiac resynchronization therapy in dyssynchronous canine hearts.

BACKGROUND The relative contribution of electromechanical synchronization and ventricular filling to the optimal hemodynamic effect in cardiac resynchronization therapy (CRT) during adjustment of stimulation-timings is incompletely understood. We investigated whether optimal hemodynamic effect in CRT requires collision of pacing-induced and intrinsic activation waves and optimal filling of the ...

متن کامل

Frontiers in congestive heart failure: Ventricular contraction abnormalities in dilated cardiomyopathy: effect of biventricular pacing to correct interventricular dyssynchrony.

OBJECTIVE To measure ventricular contractile synchrony in patients with dilated cardiomyopathy (DCM) and to evaluate the effects of biventricular pacing on contractile synchrony and ejection fraction. BACKGROUND Dilated cardiomyopathy is characterized by abnormal ventricular activation and contraction. Biventricular pacing may promote a more coordinated ventricular contraction pattern in thes...

متن کامل

lectrocardiographic imaging of cardiac resynchronization herapy in heart failure: Observation of variable lectrophysiologic responses

BACKGROUND Cardiac resynchronization therapy (CRT) for congestive heart failure patients with delayed left ventricular (LV) conduction is clinically beneficial in approximately 70% of patients. Unresolved issues include patient selection, lead placement, and efficacy of LV pacing alone. Being an electrical approach, detailed electrical information during CRT is critical to resolving these issue...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • American journal of physiology. Heart and circulatory physiology

دوره 307 3  شماره 

صفحات  -

تاریخ انتشار 2014