CT-6Rb Engineering Prospects of Negative-Ion-Based Neutral Beam Injection System from High Power Operation for the Large Helical Device
نویسندگان
چکیده
An overview on four-year operation of the negative-ion-based NBI (N–NBI) system for the Large Helical Device (LHD) is presented, and prospects of negative-ion technology for applying it to future helical fusion reactors are discussed from theses experiences. The N–NBI system was designed and constructed based on the results of R&D at NIFS. Using three beam lines, the total port-through injection power of 9 MW for 2 s has been achieved. Each beam line attained the same performance: 3.5 MW of the port-through power with the beam energy of 165 keV for hydrogen, which corresponds to the averaged negative ion current density of 25mA/cm from ion sources. Also for long pulse injections, 110 s for 0.1 MW by one ion source, and 80 s for 0.5 MW by two ion sources (one beam line) were carried out. These facts show that the negative ion technology has been established to the same power level of conventional positive ion systems. Several technical improvements needed for getting these successful results are described, and the problems that limit the present performance are clarified. Some R&D programs to solve these problems are proposed for further improvement.
منابع مشابه
Fast ion charge exchange spectroscopy adapted for tangential viewing geometry in LHD.
A tangential Fast Ion Charge eXchange Spectroscopy is newly applied on a Large Helical Device (LHD) for co/countercirculating fast ions, which are produced by high energy tangential negative-ion based neutral beam injection. With this new observation geometry, both the tangential-neutral beam (NB) and a low-energy radial-NB based on positive ions can be utilized as probe beams of the measuremen...
متن کاملAnalysis of Beam Quality Optimization of Bucket Ion Source
The bucket ion source is widely used as the high energy beam source on the high power neutral beam injector system. A hot cathode bucket ion source is studied. The main parameters which influence the performance of bucket ion source are arc voltage, filament voltage, gas inlet rate and extracted voltage. The proton ratio is the dominate parameter for the ion source. In the experiment, the chara...
متن کاملCommissioning Results of the KSTAR Neutral Beam System
The neutral beam injection (NBI) system is designed to provide the ion heating and current drive for the high performance operation and long pulse operation of the Korean Superconducting Tokamak Advanced Research (KSTAR). The KSTAR NBI consists of two beam lines. Each beam line contains three ion sources of which one ion source has been designed to deliver more than 2.5 MW of deuterium neutral ...
متن کاملCharacteristics of High-Ion-Temperature Plasmas heated by Neutral Beams in the Large Helical Device
Improvement of ion heat transport in Heliotron plasmas has been realized by upgrade of ion heating power by using low energy neutral beam (NB) in the Large Helical Device (LHD). Ion internal transport barrier (ITB) (the peaked profile of ion temperature (Ti) with steep gradient in the core region) has been formed and the central Ti of 6.8 keV has been achieved in hydrogen plasma with the line-a...
متن کاملDevelopment of Multi-mega Watt Negative Ion Sources and Accelerators for Neutral Beam Injectors
High energy and high power negative ion sources and accelerators have been developed for neutral beam (NB) injectors of future fusion machines such as International Thermonuclear Experimental Reactor (ITER). Using a 5-stage electrostatic accelerator, negative ion beam has been successfully accelerated up to the energy of 1 MeV, which is the required energy for ITER. Powerful negative ion beams ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2002