Optimization of Multi-turn Litz Wire Radiofrequency Coils for Hyperpolarized Noble Gas Imaging of Rodent Lungs at 73.5mT

نویسندگان

  • W. Dominguez-Viqueira
  • M. Carias
  • G. E. Santyr
چکیده

Introduction Hyperpolarized noble gases (HNG), He and Xe, have become a promising tool for lung MR imaging. With hyperpolarization, the available magnetization is independent of the magnetic field strength making imaging feasible at field strengths considerably lower than those used clinically. For small animal imaging, coil noise dominates over a large range of frequencies and SNR improvements are expected by reducing RF coil noise by minimizing electrical resistance especially at low frequencies [1, 2]. It has been shown that multi-strand conductors at room temperature (eg. Litz wire) can be used to reduce resistance compared to conventional (ie. solid) copper conductors up to 10MHz [2]. SNR improvements have previously been demonstrated for HNG imaging of rodent lungs with the use of Litz wire compared to solid copper [3]. More specifically, Litz wire type 2 with AWG 18 (660 strands of AWG 46) has been found to introduce negligible proximity effects between windings suggesting that further improvements in performance would be possible by taking advantage of the large number of turns possible at such low frequencies [3]. The objective of this work was to further improve RF coil performance by increasing the number of turns of Litz wire (type 2 with AWG 18; 660 strands of AWG 46) from a single turn up to 48 turns. Quality factors (Q) and image SNR measurements obtained from H phantoms for each coil were compared at 0.866 and 2.385 MHz corresponding to Xe and He Larmor frequencies at 73.5 mT. In vivo Xe and He rat lung images at 73.5 mT were also obtained. Methods Experiments were performed using a broad-band, variable field (0.01 – 0.15 T) MR imaging system for rodents [4]. Hyperpolarized xenon gas was produced by spin exchange optical pumping using a home-built, continuous-flow polarization system delivering 5mL/s gas mixture of 1 % xenon gas (enriched to 99% Xe ) with polarizations up to 15%. The polarizer used a 60W diode array laser (λ=794.8 nm, Coherent, Santa Clara, USA). Hyperpolarized He was produced by a turn-key polarizer (Helispin®, GEHC) providing polarizations up to 40 %. The imaging system used a Transmit Only/Receive Only (TORO) coil configuration. For this work the same transmit coil and similar receive coil geometries were used. Receiver coils were constructed on identical plastic formers with an inner diameter of 3.5”. Coils with 1, 2, 10, 20, 34 and 48 turns were built using Litz wire AWG 18 type 2 (660 strands of AWG 46) with windings side-by-side (i.e. no winding spacing). No spacing between windings was previously shown [3] to be the optimal when using this type of Litz wire. All coils were separately tuned using appropriate choices of tuning capacitance to 866 kHz or 2.385 MHz corresponding to Xe and He Larmor frequencies at 73.5 mT. The quality factor (Q) of each coil was measured using a vector impedance analyzer (Bravo MRI II, AEA Wireless, Inc., Vista CA, USA). The SNR was estimated from H gradient echo images (TR/TE = 30/7 ms 64 x 64 pixels and 10cm FOV) acquired with a 6cm diameter sphere, filled with saline solution doped with gadolinium (Gadoteridol 0.5mg/mL, Squibb Diagnostics, Montreal, Canada), by changing the magnetic field strength to 20.35 mT and 56 mT respectively. The SNR values were estimated using the mean value of the image signal divided by the standard deviation of the noise in the background. In-vivo Xe and He images were also obtained from the 48-turn and 38-turn Litz coils respectively in Sprague Dawley rats ventilated with a custom ventilation system using a University-approved animal care protocol. Results and Discussion Table 1 shows the Q values and SNR estimated for each coil at 0.866 and 2.385 MHz. Due to the very small inductance of the 1and 2-turn coils, tuning and matching at 0.866 MHz wasn’t possible. Higher Q values were obtained for the coils at 0.866 MHz because the size of the Litz strands was optimized for this frequency. The SNR was higher at 2.385 MHz due to the higher field strength. As expected, the SNR increased as the square-root of Q and number of turns for all cases. The maximum SNR at 2.385 MHz was obtained for the 34-turn coil and decreased thereafter as shown in Fig.1. For the 0.866 MHz case, the maximum SNR was obtained for the 48-turn coil (Fig 2), even though at this point the Q factor was lower for this coil than for the 34-turn coil. This decrease in Q for the 48-turn coil at 0.866 MHz, suggests higher numbers of turns would probably result in a decrease in the SNR, as for the 2.385 MHz case shown in Fig.1. Images of Xe and He of in vivo rat lungs at 0.866 and 2.385 MHz respectively are shown in Fig. 3, using the best coil at each frequency based on Figs. 1 and 2 (i.e. 48-turn coil for Xe and 34-turn coil for He). Conclusions Construction of low field RF coils for hyperpolarized gas imaging of rodents lung benefits from the use of Litz wire, particularly with increased number of turns where an SNR improvement of approximately 300% is possible compared to copper wire and nine times compared to single turn Litz coils. In future, the use of multi-turn, multi-layered Litz coils will be investigated. Acknowledgements: This work was supported in part by NSERC and CIHR. Thanks to Ryan Kraavanger for assistance with animal care. References 1Gilbert KM et al. Concepts in MR Part B 33B(3) 2008. 2 M. Savelainen et al. Proc. ISMRM 6, p. 840, 1987. 3Dominguez et al Proc ISMRM 17, p. 4748, 2009. 4Dominguez et al. Concepts in MR Part B, 33B(2), 2008. 5Berger et al. Proc ISMRM 16, p. 1108, 2008

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Hyperpolarized Noble Gas MR Imaging SNR comparison between 73.5 mT and 3 T in Rat Lung

Introduction In Hyperpolarized Noble Gas (HNG) MR imaging (i.e.Xe and He), the available magnetization is independent of magnetic field strength. Above a cut-off Larmor frequency when the sample (i.e. body) noise dominates the RF coil noise [1], the signal-to-noise ratio (SNR) is expected to decrease with field for band-matched imaging due to a reduction in the transverse relaxation time, T2* [...

متن کامل

MRI of the lung gas-space at very low-field using hyperpolarized noble gases.

In hyperpolarized (HP) noble-gas magnetic resonance imaging, large nuclear spin polarizations, about 100,000 times that ordinarily obtainable at thermal equilibrium, are created in 3He and 129Xe. The enhanced signal that results can be employed in high-resolution MRI studies of void spaces such as in the lungs. In HP gas MRI the signal-to-noise ratio (SNR) depends only weakly on the static magn...

متن کامل

Hardware for Performing Hyperpolarized Helium Imaging on a Clinical MR Imager

For the past forty years, magnetic resonance imaging (MRI) has been one of the most common methods for obtaining volume images of human organs. However, some organs in the human body, such as the lungs, are resistant to these techniques, due to their lack of protons. In 1994, hyperpolarized noble gas MRI was introduced, and today is viewed as the best solution to the MR imaging dilemma. The dif...

متن کامل

Hyperpolarized Noble Gas Mri of the Brain and Lungs

INTRODUCTION We are developing a new diagnostic technology: magnetic resonance imaging (MRI) and spectroscopy of hyperpolarized noble gases. Large non-equilibrium nuclear spin polarizations can be created in the spin-1/2 noble gases, He and Xe, using the technique of spin-exchange optical pumping. Such large polarizations greatly enhance the magnetic resonance detection of He and Xe, enabling h...

متن کامل

Designing and Fabrication of a New Radiofrequency Planar microcoil for mini-Nuclear Magnetic Resonance

Introduction Radiofrequency planar microcoils are used to increase the resolution of magnetic resonance images of small samples. In this study, we aimed to design and fabricate a spiral planar microcoil constructed on a double-sided printed circuit board (PCB). It has four rings with an internal diameter of 241 microns tuned and matched at 63.8 MHz. Materials and Methods To achieve the maximum ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2009