Performance of ventilators for noninvasive positive-pressure ventilation in children.

نویسندگان

  • B Fauroux
  • K Leroux
  • G Desmarais
  • D Isabey
  • A Clément
  • F Lofaso
  • B Louis
چکیده

The aim of the present study was to evaluate the performance characteristics of all the ventilators proposed for home noninvasive positive-pressure ventilation in children in France. The ventilators (one volume-targeted, 12 pressure-targeted and four dual) were evaluated on a bench which simulated six different paediatric ventilatory patterns. For each ventilator, the quality of the inspiratory and expiratory trigger and the ability to reach and maintain the preset pressures and volumes were evaluated with the six patient profiles. The performance of the ventilators showed great variability, and depended upon the type of trigger (flow or pressure), type of circuit and patient profile. Differences were observed between the preset and measured airway pressure and between the tidal volume measured by the ventilator and on the bench. Leaks were associated with an inability to detect the patient's inspiratory effort or autotriggering. No single ventilator was able to adequately ventilate the six paediatric profiles. Only a few ventilators were able to ventilate the profiles simulating the youngest patients. A systematic paediatric bench evaluation is recommended for every ventilator proposed for home ventilation, in order to detect any dysfunction and guide the choice of the appropriate ventilator for a specific patient.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effects of gas leak on triggering function, humidification, and inspiratory oxygen fraction during noninvasive positive airway pressure ventilation.

OBJECTIVES During noninvasive positive pressure ventilation (NPPV), the gas leak that commonly occurs around the mask can render NPPV ineffective. We evaluated the effects of gas leak on inspiratory trigger function during NPPV with bilevel pressure and ICU ventilators. In addition, we evaluated the effects of gas leak on fraction of inspired oxygen (Fio(2)) and humidification. METHODS Air le...

متن کامل

Increased ventilation with NiIPPV does not necessarily improve exercise capacity in COPD.

Evidence that noninvasive intermittent positive-pressure ventilation (NiIPPV) improves exercise capacity in chronic obstructive pulmonary disease (COPD) is limited. The effectiveness of different ventilators in this setting has not been studied. Three bilevel pressure support ventilators (Bipap S/T 30, Nippy2 and Vpap II ST), applied via a mouthpiece, were compared during submaximal treadmill e...

متن کامل

Noninvasive ventilation in neuromuscular disease: equipment and application.

Noninvasive support of ventilation is commonly needed in patients with neuromuscular disease. Body ventilators, which are used rarely, function by applying intermittent negative pressure to the thorax or abdomen. More commonly, noninvasive positive-pressure ventilation (NPPV) is used. This therapy can be applied with a variety of interfaces, ventilators, and ventilator settings. The patient int...

متن کامل

Technology for noninvasive mechanical ventilation: looking into the black box

Current devices for providing noninvasive respiratory support contain sensors and built-in intelligence for automatically modifying ventilation according to the patient's needs. These devices, including automatic continuous positive airway pressure devices and noninvasive ventilators, are technologically complex and offer a considerable number of different modes of ventilation and setting optio...

متن کامل

Leak compensation in positive pressure ventilators: a lung model study.

Leak compensating abilities of six different positive pressure ventilators commonly used to deliver noninvasive positive pressure ventilation, including the bilevel positive airway pressure (BiPAP) S/T-D and Quantum (Respironics Inc, Murrysville, PA, USA), 335 and O'NYX (Mallinckrodt Inc, St Louis, MO, USA), PLV 102 (Respironics), and Siemens Servo 900C (Siemens Inc, Danvers, MA, USA). Using a ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • The European respiratory journal

دوره 31 6  شماره 

صفحات  -

تاریخ انتشار 2008