Dose and image quality comparison between prospectively gated axial and retrospectively gated helical coronary CT angiography.

نویسندگان

  • C Hlaihel
  • L Boussel
  • H Cochet
  • J A Roch
  • P Coulon
  • M J Walker
  • P C Douek
چکیده

OBJECTIVE Our aim was to compare image quality, coronary segment assessability and radiation dose in prospectively gated axial (PGA) coronary CT angiography (CTA) and conventional retrospectively gated helical (RGH) coronary CTA. METHODS Institutional review committee approval and informed consent were obtained. RGH CTA was performed in 41 consecutive patients (33 males, 8 females; mean age 52.6 years), then the PGA CTA technique was evaluated in 41 additional patients (24 males, 17 females; mean age 57.3 years) all with a pre-scan heart rate of ≤70 beats per minute (bpm). Two radiologists, blinded to clinical information, independently scored subjective image quality on a five-point ordinal scale. RESULTS The mean effective dose in the PGA group was 4.7±0.9 mSv, representing a 69% dose reduction compared with the RGH CTA group (15.1±1.9 mSv, p<0.001). The mean segmental image quality score was significantly higher in the PGA group (3.4 vs 3.2) than in the RGH CTA group (p<0.005). The percentage of assessable segments was 98.1% in the PGA group and 97.3% in the RGH group (p = 0.610). CONCLUSION PGA CTA offers a significant reduction in radiation dose compared with RGH CTA, with comparable image quality for patients with heart rates below 70 bpm.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Prospectively versus Retrospectively ECG-Gated 256-Slice CT Angiography to Assess Coronary Artery Bypass Grafts — Comparison of Image Quality and Radiation Dose

OBJECTIVE In this retrospective non-randomized cohort study, the image quality and radiation dose were compared between prospectively electrocardiogram (ECG)-gated axial (PGA) and retrospectively ECG-gated helical (RGH) techniques for the assessment of coronary artery bypass grafts using 256-slice CT. METHODS We studied 124 grafts with 577 segments in 64 patients with a heart rate (HR) <85 bp...

متن کامل

Prospectively gated transverse coronary CT angiography versus retrospectively gated helical technique: improved image quality and reduced radiation dose.

PURPOSE To retrospectively compare image quality, radiation dose, and blood vessel assessability for coronary artery computed tomographic (CT) angiograms obtained with a prospectively gated transverse (PGT) CT technique and a retrospectively gated helical (RGH) CT technique. MATERIALS AND METHODS This HIPAA-compliant study received a waiver for approval from the institutional review board, in...

متن کامل

Infant Cardiac CT Angiography with 64-Slice and 256-Slice CT: Comparison of Radiation Dose and Image Quality Using a Pediatric Phantom

BACKGROUND The aims of this study were to investigate the image quality and radiation exposure of pediatric protocols for cardiac CT angiography (CTA) in infants under one year of age. METHODOLOGY/PRINCIPAL FINDINGS Cardiac CTA examinations were performed using an anthropomorphic phantom representing a 1-year-old child scanned with non-electrocardiogram-gated (NG), retrospectively electrocard...

متن کامل

Prospectively Electrocardiogram-Gated High-Pitch Spiral Acquisition Mode Dual-Source CT Coronary Angiography in Patients with High Heart Rates: Comparison with Retrospective Electrocardiogram-Gated Spiral Acquisition Mode

OBJECTIVE To assess the image quality and effective radiation dose of prospectively electrocardiogram (ECG)-gated high-pitch spiral acquisition mode (flash mode) of dual-source CT (DSCT) coronary angiography (CTCA) in patients with high heart rates (HRs) as compared with retrospectively ECG-gated spiral acquisition mode. MATERIALS AND METHODS Two hundred and sixty-eight consecutive patients (...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The British journal of radiology

دوره 84 997  شماره 

صفحات  -

تاریخ انتشار 2011