A new method of lower extremity immobilization in radiotherapy

نویسندگان

  • Xuhai Zheng
  • Tangzhi Dai
  • Xiaochuan Shu
  • Yuanxue Pu
  • Gang Feng
  • Xuesong Li
  • Dongbiao Liao
  • Xiaobo Du
چکیده

We developed a new method for immobilization of the fix lower extremities by using a thermoplastic mask, a carbon fiber base plate, a customized headrest, and an adjustable angle holder. The lower extremities of 11 patients with lower extremity tumors were immobilized by this method. CT simulation was performed for each patient. For all 11 patients, the device fit was suitable and comfortable and had good reproducibility, which was proven in daily radiotherapy.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Long Term Effects of Volar-Dorsal Wrist/ Hand Immobilization Splint on Motor Components and Function of Stroke Patients

Objectives: This study was designed to determine the effects of Volar-Dorsal Wrist/Hand Immobilization Splint on upper extremity motor components and function of stroke patients. Methods: fourteen patients were participated in this study. The patients were selected based on the inclusion and exclusion criteria, and were given the splint after a primary evaluation. They were re-evaluated afte...

متن کامل

Early Reconstructions of Complex Lower Extremity Battlefield Soft Tissue Wounds

BACKGROUND Severe lower extremity trauma as a devastating combat related injury is on the rise and this presents reconstructive surgeons with significant challenges to reach optimal cosmetic and functional outcomes. This study assessed early reconstructions of complex lower extremity battlefield soft tissue wounds. METHODS  This was a prospective case series study of battled field injur...

متن کامل

Anatomical Alignment of Lower Extremity in Subjects With Genu Valgum and Genu Varum Deformities

Purpose: Changes in lower extremity alignment in individuals with abnormality of this segments are unclear. The present study aimed to compare lower extremity alignment in subjects with genu valgum and genu varum deformities and healthy subjects  in order to understand the lower extremity alignment changes in this group.  Methods: This was a causal-comparative study. The sample comprised 120 m...

متن کامل

Botulinum Toxin Injections or Application of Splints: Impact on Spasticity, Range of Motion and Function of Upper Extremity in Chronic Stroke Patients

Spasticity or increase in muscle tone is one of the problems following stroke. Due to this increase in muscle tone, patients are confronted to problems in motor control and difficulties in activities of daily living and complications such as shortness and contracture. The aim of this study is to compare the effects of using splint or botulinum toxin injection on spasticity, range of motion and ...

متن کامل

Evaluation of Six-Dimensional Cranial Target Positioning Accuracy in Two Different Immobilization Methods Using Exactrac System

Introduction: The aim of this study was to determine the accuracy of two different immobilization methods in patient positioning in cranial radiotherapy. The six-dimensional (6D) target localization accuracy of using a dedicated stereotactic mask was compared with that of a conventional head mask by the ExacTrac system. Material and Methods: ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 7  شماره 

صفحات  -

تاریخ انتشار 2012