Effect of duration of ventricular fibrillation on defibrillation efficacy in humans.
نویسندگان
چکیده
The currently available automatic implantable cardioverter-defibrillator has proven highly successful for termination of ventricular tachycardia and fibrillation. Newer devices, however, permit lower energy shocks to be delivered initially and longer episodes of arrhythmia to occur before shocks are delivered. These changes may result in longer durations of arrhythmia before successful termination. Little is known about the effects of the duration of ventricular fibrillation on the efficacy of defibrillating shocks. In this study, we examined the efficacy of defibrillating shocks in 22 patients undergoing automatic implantable cardioverter-defibrillator implantation or generator change. Defibrillating shocks ranging from 300 to 600 V (5.9-24.2 J) were delivered in matched pairs after 5 and 15 seconds of ventricular fibrillation. For the 300-V shocks (5.9 J), defibrillation was accomplished in 82% of patients when the shocks were given after 5 seconds of ventricular fibrillation and in only 45% of patients when the shocks were delivered after 15 seconds (p less than 0.01). At higher energies, there was no difference in the efficacy of defibrillation shocks delivered after 5 compared with 15 seconds of ventricular fibrillation. The postshock aortic, systolic, and diastolic blood pressures were significantly lower when the shocks were given after 15 seconds of ventricular fibrillation than after only 5 seconds. We conclude that the duration of ventricular fibrillation affects defibrillation efficacy especially at energies that are relatively low compared with maximal device outputs and that longer episodes of ventricular fibrillation cause more postshock hemodynamic depression. These observations have implications for defibrillation threshold testing at the time of device implantation and for the design and programming of future automatic implantable antitachycardia devices.
منابع مشابه
The influence of ventricular fibrillation duration on defibrillation efficacy using biphasic waveforms in humans.
OBJECTIVES The purpose of this study was to prospectively investigate the influence of ventricular fibrillation (VF) durations of 5, 10 and 20 s on the defibrillation threshold (DFT) during implantable cardioverter-defibrillator (ICD) implantation. BACKGROUND Although the DFT using monophasic waveforms has been shown to increase with VF duration in humans, the effect of VF duration on defibri...
متن کاملEffect of Duration of Ventricular Fibrillation
The currently available automatic implantable cardioverter-defibrillator has proven highly successful for termination of ventricular tachycardia and fibrillation. Newer devices, however, permit lower energy shocks to be delivered initially and longer episodes of arrhythmia to occur before shocks are delivered. These changes may result in longer durations of arrhythmia before successful terminat...
متن کاملEffect of cervical vagal nerve stimulation on defibrillation energy: a possible adjunct to efficient defibrillation.
The efficacy of electrical defibrillation is considered to be related to the autonomic status. In search of a possible adjunct to enhance the therapeutic performance of an implantable cardioverter-defibrillator. we investigated whether parasympathetic manipulation by cervical vagal nerve stimulation (VNS) increases defibrillation efficacy. The effects of VNS on transcardiac defibrillation thres...
متن کاملA prospective randomized evaluation of biphasic versus monophasic waveform pulses on defibrillation efficacy in humans.
Biphasic waveforms have been suggested as a superior waveform for ventricular defibrillation. To test this premise, a prospective randomized intraoperative evaluation of defibrillation efficacy of monophasic and biphasic waveform pulses was performed in 22 survivors of out of hospital ventricular fibrillation who were undergoing cardiac surgery for implantation of an automatic defibrillator. Th...
متن کاملSodium Channel Block and Action Potential Prolongation
Antiarrhythmic drugs have been reported to produce variable effects on defibrillation energy requirements. However, the relation between the in vitro electrophysiologic effects of these agents and the changes in defibrillation energy requirements have not been systematically examined. Therefore, we evaluated the effects of the sodium channel blocking drugs lidocaine and procainamide, the action...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Circulation
دوره 81 5 شماره
صفحات -
تاریخ انتشار 1990