SU-E-T-114: Characterization of the Spatial Response Functions of Ionization Chambers for Photon Beam Dosimetry.

نویسندگان

  • H K Looe
  • T S Stelljes
  • D Harder
  • B Poppe
چکیده

PURPOSE The finite extension of an ionization chamber gives rise to a spatial averaging effect, known as the "volume effect". In order to provide the appropriate corrections, the response functions along its lateral and longitudinal directions are characterized using Gaussian distributions, whose standard deviations slat and slong have been determined for a large set of clinical dosimeters. METHODS Nine cylindrical ionization chambers, two parallel-plate chambers and two 2D ionization chamber arrays have been examined by scanning rectangular photon fields along their short axes. The true profiles D(x) were known from scans with a small Si diode. The ionization chambers were aligned with their symmetry axes either perpendicular or parallel to the scan direction in order to obtain slat and slong separately. In a search process, D(x) was numerically convolved with normalized one-dimensional Gaussian kernels K(x) of varying s. The best fit between the convolution product D(x) * K(x) and the measured profile M(x) of the ionization chamber was used to determine parameters slat and slong of the Gaussian kernels. RESULTS For both the lateral and longitudinal directions, very good agreement was found between M(x) and the convolution products of D(x) with Gaussian kernels K(x). For all chambers, their 2s values are similar to the cavity dimensions, which means that the "tails" of the Gaussian response functions reach into the exterior of the chambers, - an effect of the ranges of the secondary electrons. At higher photon energies response functions K(x) are slightly wider, but no detectable depth dependence has been observed. CONCLUSIONS We have shown that the response functions of ionization chambers can be described by Gaussian distributions, confirming earlier observations, and we determined their standard deviations in both the lateral and longitudinal directions. Using these response functions, appropriate correction methods determined to eliminate the volume effect can be applied.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

SU-E-T-15: Small and Nonstandard Photon Field Dosimetry Characterization Using Monte Carlo Methods.

PURPOSE To quantify uncertainty reduction in small photon field dosimetry through characterization of ionization chambers and calibration conditions using detailed Monte Carlo methods benchmarked against NIST-traceable measurements. METHODS Phase space profiles were obtained using detailed EGSnrc Monte Carlo models for a Varian 6 MV photon linear accelerator, and a NIST-traceable cobalt-60 te...

متن کامل

Some steps towards establishing a tertiary standard dosimetry laboratory at a radiotherapy department

Background: In order to deliver the precise dose to the target in radiotherapy, absorbed dose to water at the reference point should be assessed. When the calibration procedure is performed for a reference dosimeter in the 60Co beam of a Secondary Standard Dosimetry Laboratory (SSDL), the total uncertainty in absorbed dose to water (Dw) is estimated to be approximately 1.5%. This study attempts...

متن کامل

SU-E-T-415: An Ionization Chamber Array with High Spatial Resolution for External Beam Radiotherapy.

PURPOSE To characterize an ionization chamber array technology with high spatial resolution and high charge collection efficiency for external beam radiotherapy. METHODS The prototype under test is a linear array of air vented ionization chambers developed by IBA Dosimetry, consisting of 80 pixels with 3.5mm spatial resolution and 4mm3 sensitive volume. The detector was characterized in a pla...

متن کامل

Standard calibration of ionization chambers used in radiation therapy dosimetry and evaluation of uncertainties

Background: Absolute dosimetry of external beam radiotherapy is carried out by the use of ionization chambers. These chambers must be calibrated at a standard dosimetry laboratory before any use in clinical dosimetry. The secondary standard dosimetry laboratory of Iran (SSDL) has the duty of calibrating the ionization chambers used in radiotherapy centers in Iran. Materials and Methods...

متن کامل

Dosimetric Evaluation of Linac Photon Small Fields using MAGIC Polymer Gels

Introduction: In radiotherapy, methods of treatment planning are becoming increasingly more complicated. This requires verification of the doses delivered to increasingly smaller and more precise regions. Radiotherapy techniques are continuously employing smaller and smaller field sizes to deliver tighter radiation doses with higher therapeutic ratios, generating interest among researchers to p...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Medical physics

دوره 39 6Part11  شماره 

صفحات  -

تاریخ انتشار 2012