Comparative study of four microporous filters for concentrating viruses from drinking water.

نویسندگان

  • W Jakubowski
  • W F Hill
  • N A Clarke
چکیده

Four microporous virus-absorbent filter media for recovering low levels of virus from 380 liters of drinking water were compared. In addition two of the filter media were compared with 1,900 liters of drinking water. The filter media evaluated were MF nitrocellulose membranes (293 mm), AA Cox M-780 epoxy-fiberglass-asbestos disks (267 mm), K-27 yarn-wound fiberglass cartridges + AA Cox M-780 disks (127 mm), and Balston epoxy-fiberglass tubes (24.5 by 63.5 mm). The filters were used to concentrate seeded poliovirus from 380 liters of finished drinking water. Sodium thiosulfate was added to the drinking water to neutralize chlorine, and hydrochloric acid was added to adjust the pH to 3.5. Virus was eluted from the filters with glycine-NaOH buffer at pH 11.5. In terms of virus recovery efficiency, the filter media ranked Balston greater than Cox 267-mm greater than MF 293-mm congruent to K-27 + Cox 127-mm, but differences were slight. The Balston filters and holders were also superior to the other systems in terms of size, weight, cost, and handling factors. Experiments with 2- and 8-mum porosity Balston filters showed no statistically significant difference in virus recovery. Virus was readily detected by the Balston and the MF 293-mm systems at input levels of 12 to 22 PFU/1,900 liters. Preliminary experiments indicated that an elution pH lower than 11.5 may be satisfactory.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

New electropositive filter for concentrating enteroviruses and noroviruses from large volumes of water.

The U.S. Environmental Protection Agency's information collection rule requires the use of 1MDS electropositive filters for concentrating enteric viruses from water, but unfortunately, these filters are not cost-effective for routine viral monitoring. In this study, an inexpensive electropositive cartridge filter, the NanoCeram filter, was evaluated for its ability to concentrate enteroviruses ...

متن کامل

Concentrating Toxoplasma gondii and Cyclospora cayetanensis from surface water and drinking water by continuous separation channel centrifugation.

AIMS To evaluate the effectiveness of continuous separation channel centrifugation for concentrating Toxoplasma gondii and Cyclospora cayetanensis from drinking water and environmental waters. METHODS AND RESULTS Ready-to-seed vials with known quantities of T. gondii and C. cayetanensis oocysts were prepared by flow cytometry. Oocysts were seeded at densities ranging from 1 to 1000 oocysts l(...

متن کامل

Immunoaffinity concentration and purification of waterborne enteric viruses for detection by reverse transcriptase PCR.

To assess the risks from viral contamination of drinking-water supplies, there is a clear need for methods to directly detect viral pathogens. In this study, we developed a broad-spectrum immunocapture method for concentration and purification of enteric viruses. The method involved indirect antibody capture (AbCap) of intact viruses followed by release of virion genomic RNA and reverse transcr...

متن کامل

Survey of fungal flora in the water of old and new distribution System in Aradan city

One of the great concerns of potable water consumers regarding its quality is the pollution of potable water with pathogenic microorganisms. Fungi in drinking water are responsible for changing the taste and odor of water. Health problems are possible, originating from mycotoxins, animal pathogens and allergies. Water samples were collected between December 2014 and June 2015 from different sit...

متن کامل

New method using a positively charged microporous filter and ultrafiltration for concentration of viruses from tap water.

The methods used to concentrate enteric viruses from water have remained largely unchanged for nearly 30 years, with the most common technique being the use of 1MDS Virozorb filters followed by organic flocculation for secondary concentration. Recently, a few studies have investigated alternatives; however, many of these methods are impractical for use in the field or share some of the limitati...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Applied microbiology

دوره 30 1  شماره 

صفحات  -

تاریخ انتشار 1975