[Comparison of two osmometers at the clinical chemistry laboratory].

نویسندگان

  • N Belhouachi
  • S Jaisson
  • R Garnotel
  • P Gillery
چکیده

Measurement of osmolality and calculation of osmolar gap are useful diagnostic tools in pathological situations such as hyponatremia, or intoxication by methanol or ethylene glycol. It is thus necessary to handle reliable systems of osmolality measurement. The aim of this study was to compare performances of two currently available osmometers, Fiske 210 and Advanced 3300 devices, both of them being distributed by Radiometer S.A.S. society, in order to determine the best criteria for purchase. This study showed very good performances of repeatability and reproductibility for both analyzers (CV< 2.1%) and a good correlation of results between them and with the osmometer routinely used in the laboratory. Other criteria such as a more suitable praticability for our needs and a better quality/price ratio orientated our choice towards Fiske 210 osmometer.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of the "Auto-Stat 6010" automatic osmometer and its comparison with the "digimatic-advanced 3DII" manual osmometer.

The results are presented of a comparative study between two osmometers, a manual one, Digimatic-Advanced 3DII (Advanced Instruments, Medical Europa, Barcelona), and an automatic one, Auto-Stat 6010 (Kyoto, Daiichi, Kagaku, Menarini, Firenze). Both osmometers have the same operation principle, but they employ different systems for determination of the freezing point depression. Both instruments...

متن کامل

Randomized comparison of in vivo performance of two point-of-care tear film osmometers

PURPOSE To compare the in vivo precision of two commercially available point-of-care osmometers among normal subjects with no dry eye disease. METHODS Twenty healthy adults with healthy ocular surfaces were evaluated by licensed eye care practitioners. All subjects had low Ocular Surface Disease Index score (<5), normal tear breakup time (>10 seconds), and no evidence of corneal fluorescein s...

متن کامل

Comparison of kinetic study and protective effects of biological dipeptide and two porphyrin derivatives against metal cytotoxicity in human lymphocytes

In this research, dipeptide (his-β-alanine) and porphyrin derivatives were choosen for comparing chelating ability of toxic metals such as Al3+, Cu2+, Hg2+ and Pb2+ in vitro. The reason for choosing these two compounds is that both of them are naturally present in biological systems and comparison of chelating ability of these two compounds has not yet been done. Synthesis and comparison of kin...

متن کامل

Comparison of kinetic study and protective effects of biological dipeptide and two porphyrin derivatives against metal cytotoxicity in human lymphocytes

In this research, dipeptide (his-β-alanine) and porphyrin derivatives were choosen for comparing chelating ability of toxic metals such as Al3+, Cu2+, Hg2+ and Pb2+ in vitro. The reason for choosing these two compounds is that both of them are naturally present in biological systems and comparison of chelating ability of these two compounds has not yet been done. Synthesis and comparison of kin...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Annales de biologie clinique

دوره 65 5  شماره 

صفحات  -

تاریخ انتشار 2007