Femtosecond laser versus manual clear corneal incision in cataract surgery.
نویسندگان
چکیده
PURPOSE To compare functional and morphological outcomes of femtosecond laser clear corneal incision (CCI) versus manual CCI during cataract surgery. METHODS Sixty eyes of 60 patients who underwent CCI during cataract surgery were randomized into two groups: femtosecond laser CCI (30 eyes) and manual CCI (30 eyes). RESULTS There were no significant between-group differences in uncorrected distance visual acuity, corrected distance visual acuity, surgically induced astigmatism, and corneal aberrations. Keratometric astigmatism was significantly lower in the femtosecond laser CCI group compared to the manual CCI group at 30 and 180 days (P < .05). Central endothelial cell count was significantly higher in the femtosecond laser CCI group compared to the manual CCI group at 7 and 30 days postoperatively (P < .05). A lower increase of corneal thickness at the incision site was observed at 30 and 180 days postoperatively in the femtosecond laser CCI group compared to the manual CCI group (P < .05). In addition, femtosecond laser CCI showed a better morphology (lower percentage of endothelial and epithelial gaping and endothelial misalignment) compared to manual CCI at different time points. Total phacoemulsification time was significantly lower in the femtosecond laser CCI group (P < .05). CONCLUSIONS The femtosecond laser procedure was safe, efficient, and less damaging, as evidenced by lower central endothelial cell loss, lower increase of corneal thickness at the incision site, and better tunnel morphology compared to the manual technique.
منابع مشابه
Standard manual capsulorhexis / Ultrasound phacoemulsification compared to femtosecond laser-assisted capsulorhexis and lens fragmentation in clear cornea small incision cataract surgery
BACKGROUND Femtosecond-laser assisted clear cornea cataract surgery may hold promise in safer and more effective procedures. We decided to perform a comparative study to standard manual incision phacoemulsification surgery. METHODS This is a single-center, single-intervention, and prospective comparative data evaluation of 133 consecutive cases subjected to cataract surgery. Group-A (Phaco), ...
متن کاملCorneal biomechanical effects: small-incision lenticule extraction versus femtosecond laser-assisted laser in situ keratomileusis.
PURPOSE To compare the biomechanical properties of the cornea after small-incision lenticule extraction (lenticule extraction group) with those after femtosecond laser-assisted laser in situ keratomileusis (femtosecond LASIK group). SETTING Tianjin Eye Hospital & Eye Institute, Tianjin Key Laboratory of Ophthalmology and Visual Science, Tianjin Medical University, Tianjin, China. DESIGN Pro...
متن کاملEvaluation of femtosecond laser clear corneal incision: an experimental study.
PURPOSE To evaluate the changes of corneal topography following femtosecond laser and manual clear corneal incision (CCI). METHODS Inflation testing was performed in 14 human eye globes to evaluate the topographic response of the cornea to CCIs. In seven samples (femtosecond laser group), a 2.75-mm three-plane CCI was created using the iFS femtosecond laser (Abbott Medical Optics, Inc., Santa...
متن کاملResident surgeon efficiency in femtosecond laser-assisted cataract surgery
PURPOSE Comparison of resident surgeon performance efficiencies in femtosecond laser-assisted cataract surgery (FLACS) versus conventional phacoemulsification. PATIENTS AND METHODS A retrospective cohort study was conducted on consecutive patients undergoing phacoemulsification cataract surgery performed by senior ophthalmology residents under the supervision of 1 attending physician during a...
متن کاملDescemet Membrane Detachment in Femtosecond Laser-Assisted Cataract Surgery.
PURPOSE To report a case series of 4 patients with Descemet membrane detachment (DMD) after undergoing femtosecond laser-assisted cataract surgery incisions. METHODS Case report. RESULTS DMD was noted at the secondary incision (n = 2) or at the main incision (n = 2). All the secondary incision and 1 main incision DMD were resolved with intraoperative maneuvers. Delay in recognizing DMD intr...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of refractive surgery
دوره 30 1 شماره
صفحات -
تاریخ انتشار 2014