A Comparative Performance Analysis of Four Control Algorithms for a Three Phase Shunt Active Power Filter

نویسندگان

  • E. Latha Mercy
  • R. Karthick
  • S. Arumugam
چکیده

Shunt Active Power Filters (SAPFs) represent the most important and widely used filter in industrial purposes due to the fact that, they not only eliminate the harmonic current with a neglected amount of active fundamental current supplied to compensate system losses, but also they are suitable for a wide range of power ratings. One of the key issues for a proper implementation of an active filter is to use a good control algorithm for reference current generation. This paper presents a comparative analysis of the effectiveness of four approaches for determining the reference compensation currents of SAPF to maintain sinusoidal source currents supplied to nonlinear loads according to IEEE-519 standard. The approaches to be compared include the instantaneous reactive power theory, synchronous reference frame theory, synchronous detection method and perfect harmonic elimination method. Models of a power line with a nonlinear load using the above four approaches are developed using MATLAB-Simulink and are simulated for both balanced and unbalanced conditions.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Hybrid Control Method for Stable Operation of Active Power Filters in Three-Phase Four-Wire Networks

The main goal of this study is the use of Lyapunov’s stability theory to a three-phase four-wire shunt active power filter (SAPF), since this method has been applied effectively to other areas of converter. The dynamic model of the SAPF is first established, after that, a combination of fuzzy tracking control and Lyapunov function is suggested in order to impose a desired transient waveform on ...

متن کامل

Performance Scrutiny of Two Control Schemes Based on DSM and HB in Active Power Filter

This paper presents a comparative analysis between two current control strategies, constant source power and generalized Fryze current, used in Active Power Filter (APF) applications having three different modulation methods. The Hysteresis Band (HB) and first-order Delta-Sigma Modulation (DSM) as well as the second-order DSM is applied. The power section of the active power filter is viewed as...

متن کامل

Improving the performance of UPQC under unbalanced and distortional load conditions: A new control method

This paper presents a new control method for a three-phase four-wire Unified Power Quality Conditioner (UPQC) to deal with the problems of power quality under distortional and unbalanced load conditions. The proposed control approach is the combination of instantaneous power theory and Synchronous Reference Frame (SRF) theory which is optimized by using a self-tuning filter (STF) and without us...

متن کامل

A Novel Reference Current Calculation Method for Shunt Active Power Filters using a Recursive Algebraic Approach

This paper presents a novel method to calculate the reference source current and the referencecompensating current for shunt active power filters (SAPFs). This method first calculates theamplitude and phase of the fundamental load current from a recursive algebraic approach blockbefore calculating the displacement power factor. Next, the amplitude of the reference mains currentis computed with ...