Effect of intragastric barostat bag on proximal and distal gastric accommodation in response to liquid meal.

نویسندگان

  • M W Mundt
  • T Hausken
  • M Samsom
چکیده

The barostat is the gold standard for measurement of proximal gastric accommodation. Ultrasonography can be used to measure gastric volume. The aim was to investigate the effects of the barostat bag on gastric accommodation and transpyloric flow. Accommodation after a liquid meal (300 ml, 450 kcal) was measured twice at random in eight healthy volunteers. Proximal accommodation was measured once using barostat and once using ultrasound (US). Antrum accommodation was measured using US. Bag volume (BV), antral area (AA), proximal gastric area, and proximal gastric diameter (PGD) data were assessed before and 1, 5, 15, 30, 40, 50, and 60 min postprandially. Transpyloric flow was measured using Doppler 1-5 min postprandially. Fasted, AA size was not affected by the barostat bag (1 mmHg > minimal distension pressure; 2.7 +/- 0.5 vs. 2.6 +/- 0.3 cm(2)). Postprandially, AAs were larger with the bag present (ANOVA, P < 0.04). Maximum AA was reached with the bag in 5 min, without the bag in 1 min postprandially (15.1 +/- 2.3 vs. 9.4 +/- 1.5 cm(2); P < 0.03). Furthermore, AAs were related to BVs (r = 0.57; P < 0.01). After bag deflation, AA decreased (11.9 +/- 1.8 to 7.0 +/- 0.9 cm(2); P = 0.02) and was comparable with the 60-min AA size without the bag (7.1 +/- 1.2 cm(2); P = 0.76) present. Proximal gastric radius calculated from the BVs and PGDs was larger with the bag present (ANOVA, P < 0.001). No effect on early gastric emptying was observed. Postprandially, the barostat bag causes dilatation of the antrum due to meal displacement without influencing early gastric emptying. This antral dilatation is likely to induce exaggerated proximal gastric relaxation observed in studies using the barostat to evaluate fundic accommodation.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Gastric accommodation and motility are influenced by the barostat device: Assessment with magnetic resonance imaging.

The barostat is considered the gold standard for evaluation of proximal gastric motility especially for the accommodation response to a meal. The procedure is invasive because it involves the introduction of an intragastric catheter and bag and is not always well tolerated. Moreover, the barostat bag itself may influence motility. Nowadays magnetic resonance imaging (MRI) is able to measure sev...

متن کامل

Running head: Gastric accommodation and motility by MRI and barostat

Background: The barostat is considered the gold standard for evaluation of proximal gastric motility especially for the accommodation response to a meal. The procedure is invasive because it involves the introduction of an intragastric catheter and bag and is not always well tolerated. Moreover, the barostat bag itself may influence motility. Nowadays Magnetic Resonance Imaging (MRI) is able to...

متن کامل

Differences in the sensorimotor response to distension between the proximal and distal stomach in humans.

BACKGROUND It is not known which region of the stomach is responsible for symptom generation or whether symptoms induced by gastric distension are region specific. Also, it is unclear whether low level gastric distension has a modulatory role on gastric tone and mechanosensitivity. AIMS To define differences in the sensorimotor response to distension between proximal and distal gastric disten...

متن کامل

OESOPHAGEAL DISEASE Intragastric maldistribution of a liquid meal in patients with reflux oesophagitis assessed by three dimensional ultrasonography

Background and aims: Our aim was to study intragastric volume and distribution of a liquid meal in patients with reflux oesophagitis using three dimensional ultrasonography. Methods: Twenty patients and 20 healthy controls underwent ultrasonographic measurements of the stomach using a position sensor based on magnetic scanhead tracking for acquisition of three dimensional images. In vivo accura...

متن کامل

Intragastric maldistribution of a liquid meal in patients with reflux oesophagitis assessed by three dimensional ultrasonography.

BACKGROUND AND AIMS Our aim was to study intragastric volume and distribution of a liquid meal in patients with reflux oesophagitis using three dimensional ultrasonography. METHODS Twenty patients and 20 healthy controls underwent ultrasonographic measurements of the stomach using a position sensor based on magnetic scanhead tracking for acquisition of three dimensional images. In vivo accura...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • American journal of physiology. Gastrointestinal and liver physiology

دوره 283 3  شماره 

صفحات  -

تاریخ انتشار 2002