Reduced FOV spinal muscle DWI with single-shot interleaved multi-slice inner volume stimulated echo DW-EPI
نویسندگان
چکیده
Introduction: Atrophy of spinal muscles is associated with degenerative disc disease, alignment disorders and eventually back pain. Diffusion-weighted (DW) MRI of skeletal muscle has been proposed as a sensitive marker of denervation-induced muscle atrophy [1]. However, DW-MRI of spinal muscles remains challenging due to the muscle short T2 and the sensitivity of single-shot EPI to off-resonance effects. Stimulated-echo preparation has been used to overcome the SNR limitations in muscle DW EPI (enabling eddy current compensation without additional TE increase [2]) and has been recently combined with parallel imaging [3]. However, the use of phased array coils to increase the phase encoding bandwidth depends on the sensitivity profiles of the receiver coils and is not in general feasible in spine DWI. Reducing the FOV in the phase encoding direction is another way to increase the spatial resolution of localized muscle DWI scans without lengthening the readout with the additional benefit of excluding the artifact prone regions of the FOV. There have been a number of techniques proposed to reduce the FOV in spin-echo prepared DW-EPI of white matter regions, including outer volume suppression [4] and 2D RF excitation [5]. Outer volume suppression is limited by the performance of the regional saturation pulses and 2D RF excitation can increase the echo time. Multi-slice inner volume imaging has been also achieved in twice-refocused spin-echo (TRSE) acquisitions, by making the two refocusing pulses selective in the phase encoding direction [6]. The latter approach can provide good inner volume excitation profiles with modest decrease in SNR for interleaved multi-slice acquisitions, but it has been studied only in the context of spin-echo preparation [6]. Goal of the present work is the development of a DW stimulated echo sequence with interleaved multi-slice inner volume imaging to improve the resolution of spinal muscle DWI. Materials & Methods: Pulse sequence description: Refocusing pulses selective in the phase encoding direction are added before the second 90o pulse and after the third 90o pulse of a stimulated echo prepared DW-EPI sequence with eddy current compensation [2] (Fig 1a). Fig. 1b shows the magnetization evolution while imaging slice 1 in an interleaved acquisition of 2 slices. By setting the area of crushers around the refocusing pulses (A1 and A2) not equal, the magnetization within slice 1 outside the inner volume of interest is dephased and the desired inner volume excitation is achieved. The first 90o pulse is a fat suppressive spatial spectral excitation pulse. In vivo measurements: A head-neck-spine array coil was used to scan the lumbar spine muscles of one healthy subject on a 3 T full-body GE scanner. DWI measurements were performed using the reduced-FOV sequence of Fig. 1a with the following parameters: TR/TE=8000/40 ms, FOV=32x9 cm, 4 slices with 12 mm thickness, 128x40 matrix size, 8 overscans, δ/Δ=5/170 ms, 3 directions, Nex=16, b=500 s/mm with as scan time of 8 min and 32 s. The same region was also scanned with the full-FOV stimulated echo sequence [2] with the same parameters except for: TE=31 ms, FOV=32x32 cm, 128x128 matrix size. A T2-weighted FSE scan using IDEAL for fat suppression was also acquired for anatomical reference. Results & Discussion: Sequence tradeoffs: The addition of the two refocusing pulses increases the echo time by 2d where d is the duration of the added refocusing pulse with the accompagnying crushers. The T2 and T1 relaxation-induced signal loss of the proposed sequence is compared with the relaxation induced signal loss of the inner volume TRSE sequence [6]. The proposed sequence leads to higher SNR than the inner volume TRSE for b>500 s/mm (Fig. 2a). Another important aspect of sequences with excitation/refocusing slabs in the phase encoding direction is the characterization of the T1-induced longitudinal magnetization loss in multi-slice acquisitions [7,8]. The magnetization within the inner volume and outside the imaging slice experiences two 180o pulses separated by TM+2d. Since the SNR-optimal stimulated echo diffusion timing requires long TM [2], the proposed sequence when performing at optimal diffusion time Δopt enables multi-slice interleaved acquisition but with a considerable SNR loss (Fig. 2b). However, if the stimulated echo diffusion timing is modified such that the diffusion time Δ is 30% lower than the optimal diffusion time Δopt, a considerable increase of the longitudinal magnetization can be achieved for multi-slice interleaved acquisition (Fig. 2b) without significant loss of the transverse magnetization (Fig. 2a). In vivo results: Fig. 3 shows the cropped full-FOV and reducedFOV lumbar spine muscle DWI results (voxel size is 2.5x2.5x12 mm). Muscle contours have been drawn based on the T2-weighted FSE. The full-FOV EPI data suffer from significant geometric distortions, showing as compression of the erectus muscle anatomy in the A/P direction (arrow 1). The full-FOV data suffer also from fat-induced chemical shift artifacts that bias ADC (arrow 2). When comparing the reduced-FOV data with the full–FOV data, there is an expected SNR loss due to the reduction of the readout duration. However, the geometric distortions and the displacement of the chemical shift artifact are significantly reduced using the reduced-FOV acquisition (arrows 1 and 2). Conclusion: A reduced-FOV DW-EPI approach, combing stimulated echo preparation with inner volume multi-slice imaging is developed for immune to off-resonance effects DWI of spinal muscles. Future work could include application of this sequence for high resolution DWI in other short T2 tissues of the spine (marrow, disc). References: [1] Zhang et al, Exp Neurol 212:448, 2008, [2] Steidle et al, MRM. 55:541, 2006, [3] Karampinos et al, ISMRM 2010, p. 880, [4] Wilm et al, MRM 57:625, 2007, [5] Saritas et al, MRM 60:468, 2008, [6] Dowell et al, JMRI 29:454, 2009, [7] Jeong et al, MRM 54:1575, 2005, [8] Kim et al, JMRI 30: 1068, 2009. Acknowledgement: The present work was funded by NIH-R01 AG17762 and NIH-P30 AR058899. Fig. 3: In vivo lumbar spine muscles results. The dashed box shows the inner volume FOV. Fig. 1: (a) Schematic of pulse sequence diagram (diffusion gradients are in black and eddy current compensating gradients are in gray), (b) evolution of magnetization while imaging slice 1 in an interleaved acquisition of 2 slices.
منابع مشابه
DWI of the spinal cord with reduced FOV single-shot EPI.
Single-shot echo-planar imaging (ss-EPI) has not been used widely for diffusion-weighted imaging (DWI) of the spinal cord, because of the magnetic field inhomogeneities around the spine, the small cross-sectional size of the spinal cord, and the increased motion in that area due to breathing, swallowing, and cerebrospinal fluid (CSF) pulsation. These result in artifacts with the usually long re...
متن کاملMulti-Slice Parallel Excitation Reduced FOV Imaging for Rodent EPI Applications
Introduction Echo-planar imaging (EPI) offers major advantages over conventional MR imaging, including reduced imaging time and the ability to image rapid physiologic processes [1]. However, signal decay and off-resonance effects limit the possible duration of the EPI echo train, requiring high resolution EPI to combine k-space signals from several sequential excitations. Multiple shot techniqu...
متن کاملDiffusion-weighted imaging of the spine with readout-segmented (RS)-EPI
Introduction: The development of diffusion-weighted imaging (DWI) of the spine has been hindered by the large off-resonance effects problematic for single-shot EPI. Overcoming these restrictions would open up applications ranging from the diagnosis of spinal cord infarction, vertebral body fractures, lymphoma, trauma, and many other disorders. Navigated interleaved EPI has been shown to overcom...
متن کاملMulti-shot Diffusion-Weighted Split-Echo PROPELLER MRI of the Abdomen
Introduction Diffusion-weighted MRI (DWI) provides a non-invasive method for in vivo evaluation of tissue water mobility. Most DWI studies employ single-shot DWEPI techniques which can suffer severe artifacts and image distortion in abdominal imaging applications. Multi-shot TSE-based DW-PROPELLER [1] may overcome these limitations. DW-PROPELLER for brain [2] and abdominal [3] imaging has demon...
متن کاملHigh-Resolution DWI outside the CNS using Reduced-FOV Single-Shot EPI
Introduction: Diffusion weighted imaging (DWI) has recently been recognized as a potential clinical tool for the diagnosis and treatment monitoring of cancer outside the central nervous system [1-3]. Even though single-shot EPI (ss-EPI) is the preferred method for these applications, its resolution is limited. Recently, a reduced field-of-view (FOV) method has been presented for high resolution...