3d Wall Motion Tracking: Implementing a New Tool in Daily Clinical Practice
نویسنده
چکیده
Since the introduction of ultrasound in cardiology, the wish to quantify cardiac function was the driver for the development of new technologies. M-mode, which projects speckle information of cardiac struc tures over time, is so to speak the initial form of one-dimensional wall motion tracking. Twodimen sional speckle tracking is useful, has some limitations, though, because the heart has three dimensions. Now, the recently developed threedimensional wall motion tracking (3D WMT) techno logy provides a new diagnostic tool. 3D WMT offers a new way to analyze the left ventricle and a new concept to assess its function. Moreover, it is not time-consuming and can thus be used as a routine analysis tool in daily clinical practice. 3D WMT is a new technique that can assess global and regional left ventricular function in a fast and comprehensive way. Its use may help the clinician to save time without having to make compromises in terms of completeness and accuracy of the analysis. Introduction Traditionally, global left ventricular (LV) function has been evaluated using M-mode or two-dimensional (2D) echocardiography. More recently, threedimen sional (3D) echocardiography has been intro duced in daily clinical practice. Segmen tal wall motion, however, has been difficult to assess. It is usually performed by measuring endocardium thickening, but this approach is limited by huge intraobserver and interobserver variability. Strain and strain-rate imaging have emerged as a quanti tative technique to solve this problem (1). Both measurements have been obtained from tissue Doppler imaging (TDI), but TDI-based strain and strain rate have several limitations: angledependent measurements (due to the use of Doppler) and simul taneous opposite deformation in the long and short axes (2). A new technique called wall motion tracking (WMT) seems to solve the problem associated with TDI. The recent development of three-dimensional wall motion tracking (3D WMT) technology provides a new diagnostic tool: it is a fast new way to analyze the left ventricle and a new concept to assess left ventricular function. Wall Motion Tracking Speckle in ultrasound images is a phenomenon caused by interference of waves from randomly distributed scatterers in the myocardium. These scatterers are too small to be detected by ultrasound technology. Speckle degrades both spatial and contrast resolution by creating fine false structures, the so-called speckle noise. This phenomenon has a very important characteristic: speckle moves with the tissue. Thus, the speckle pattern follows the myocardial motion. Furthermore, Adriana Saltijeral Cerezo, MD , Leopoldo Pérez de Isla, MD, PhD, FESC , Juan Rementería , Willem Gorissen , José Zamorano, MD, PhD, FESC, EAE president . 1 Unidad de Imagen Cardiovascular, Hospital Clínico San Carlos, Madrid, Spain 2 Toshiba Medical Systems Europe 3D WALL MOTION TRACKING: IMPLEMENTING A NEW TOOL IN DAILY CLINICAL PRACTICE Fig. 1: Left ventricular septum M-mode shows how speckle moves with tissue. Fig. 2: Left ventricular 2D WMT evaluation. The analysis of a short axis view is shown. The analysis of the whole left ventricle is very time-consuming. 2 3D wall motion tracking: Implementing a new tool in daily clinical practice Fig. 4: Left ventricular semi-automatic tracking. The user sets three markers in planes A and B. The software detects the LV endocardium and the epicardium. See text for details. Fig. 3: 3D WMT detects speckle motion in three dimensions. each region of the myocardium shows a different speckle pattern due to the characteristic randomness of this phenomenon. Thus, a unique pattern is created for any selected region that can identify this region and the displacement of the region in the next frame. Motion is analyzed by integrating frame-to-frame changes (3). Velocities can be calculated by the geometric shift of each speckle. The basic parameter of this information is displacement, and based on this value other parameters can be obtained (4, 5, 6). Because M-mode projected the speckle information of the cardiac structures over time, it was so to speak the first form of one-dimensional speckle tracking (Fig. 1). One of the most important advantages of this method studied by Sivesgaard et al is the fact that there is no angle-dependency and multiple parameters can be calculated in different views. (7) 2D Wall Motion Tracking Two-dimensional wall motion tracking (2D WMT) consists of a template image created using a local myocardial region in the starting frame of the image data. In the next frame an algorithm searches for the local speckle pattern that most closely matches the template. A movement vector is created using the location of the template and the matching pattern in the subsequent frame. Multiple templates are used to observe movement of the entire myocardium. The process is repeated by creating new templates and observing their movement in the subsequent frames until the entire cardiac c ycle has been assessed. Classically, strain and strain rate have been parameters obtained from tissue Doppler data (1). Nevertheless, WMT technology allows a new and more direct approach to obtain these parameters. 2D WMT can quantify regional myocardial deformation independently of insonation angle (7) and thus simultaneously assess long and short axis deformation. In this way, circumferential, radial and longitudinal strain can be obtained (2, 8, 9). Furthermore, other parameters such as rotation, shear, twist and torsion may be evaluated (Fig. 2). WMT-derived strain and strain rate provide clinical relevant information in a huge number of cardiac diseases. Ingul et al analyzed patients with myocar dial infarction and showed no difference between TDI and 2D WMT parameters in the infarcted area. Their results, however, showed that automated analysis methods were faster than and as accurate as manual analysis (10). Seo et al studied thirty-three patients with severe symptomatic heart failure despite optimal pharmacologic therapy and showed that assessing left ventricle dyssynchrony using speckle tracking echocardiography results in a high rate of success for dyssyn chrony assessment and clinically acceptable repro ducibility (11). Similar results were obtained by Delgado et al (12). 3D Wall Motion Tracking The heart has three dimensions. Cardiac motion is 3D and speckle noise moves in the three spatial directions. Thus, 2D WMT is limited because it cannot assess movement in the third dimension. The main difference between 2D and 3D WMT is that, although both techniques use ultrasound image data to detect movement of the myocardium, 2D WMT employs 2D movement or the projection of 3D movement into a 2D plane, whereas 3D tracking assesses real movement in 3D, not just a projection. 2D data is not used in this technique at any point. 3D WMT was developed as a new 3D wall motion tracking: Implementing a new tool in daily clinical practice 3 Fig. 5a: A patient with hypertrophic cardiomyopathy. The type of display selected to present the results of the analysis of the left ventricular rotation is the so-called “plastic bag”. Fig. 5b: In this case, the selected parameter is the left ventricular torsion and the type of display chosen is the “doughnut view”. Fig. 5c: Polar map. Another way to present the 3D WMT results graphically. application that can be used for regional wall motion analysis of the entire LV and allows to obtain real 3D indices and to assess 3D wall motion precisely with an improved integration of heart structures (Fig. 3). It is capable of displaying results for the entire myocardium using a single dataset to assess truly global LV. An overall dataset enables the user to observe new indices (e.g. torsion), true 3D strain and a host of other previously unobserved parameters (13). 3D speckle tracking has several advantages: all vectors of tissue tracking are tracked within the full volume. Moreover, lower volume rates can be used and it provides a better vector calculation which is more adequate for clinical scanning conditions and there is no loss of the speckle particle in 3D. 3D WMT requires the new Artida system and the PST-25SX 1 MHz to 4 MHz phased-array matrix transducer, both by Toshiba Medical Systems Corporation, Otawara, Japan. These two devices optimize 3D image acquisition. The matrix transducer can scan a user-selected volume that can be adjusted from 15o x 15o to 90o x 90o. For realtime purposes, one-beat acquisition is used and a triggered acquisition mode is available for advanced analyses. In the triggered mode (the mode used for 3D WMT evaluation), a live monitoring mode allows the user to monitor the reconstruction of the full-volume data set. The standard application setting is the use of four subvolumes of 90o x 22.5o, which results in a 90o x 90o triggered full volume in four heart cycles. During the acquisition, a five-plane view of the fourand two-chamber apical views and short axis planes at apex, mid and base of the LV is guiding the user to keep the best trans ducer position and updates the acquisition process continuously. During acquisition it is of great impor tance for the subvolume to match well which can be monitored on the screen. If a mismatch appears, the examiner can continue the acquisition process until the mismatch disappears in the following heart cycles shown on the monitor. A retrospective acqui sition method is used and after ‘freeze’ the best fullvolume datasets can be selected from the image memory. A template for the B and C planes is available to set the right orientation of the A, B and C planes in order to achieve optimum plane selection. Each 3D data set is displayed in a five-plane view: (A) an apical four-chamber view; (B) a second apical view orthogonal to plane A; and (C) three short-axis planes: plane C1 in the apical region, plane C2 in the mid-ventricle and plane C3 at the basal portion of the left ventricle. The user then sets three markers on planes A and B; in each plane, one marker is set at the apex and the other two at the edges of the mitral valve ring. The software then detects the LV endocardium, and the user sets a default thickness for the myocardium (Fig. 4). The software splits the LV into 16 segments automatically according to the American Heart Association standards for myocardial segmentation. After the markers have been selected, the system performs the 3D WMT analysis through the entire cardiac cycle. The selection of the LV shape is semiautomatic and the tracking process is automated, but the user can adjust the results of the tracking process if needed. Finally, the results of the 3D WMT analysis are presented as averaged values for each segment.
منابع مشابه
A study on the accuracy of motion tracking of thoracic tumors at radiotherapy with external surrogates
Introduction: In radiotherapy with external surrogates, exact information of tumor position is one of the key factors that improves treatment delivery. Many dynamic tumors in thorax region of patient move mainly due to respiration and are known as intra-fractional motion error that must be compensated, as well. One of clinical strategy is using Stereotactic Body Radiation Thera...
متن کاملNeuroTracker Three-Dimensional Multiple Object Tracking (3D-MOT): A Tool to Improve Concentration and Game Performance among Basketball Athletes
Background. Basketball is a dynamic sport where athletes are expected to observe the fast movements of team players and opponents in a performance. This condition requires a collective focus on the stipulated tasks, to achieve peak performance. Besides, training is frequently performed to improve concentration and athlete performance. This instigates the need for technology-based methods, inclu...
متن کاملThe agreement between 3D, standard 2D and triplane 2D speckle tracking: effects of image quality and 3D volume rate
Comparison of 3D and 2D speckle tracking performed on standard 2D and triplane 2D datasets of normal and pathological left ventricular (LV) wall-motion patterns with a focus on the effect that 3D volume rate (3DVR), image quality and tracking artifacts have on the agreement between 2D and 3D speckle tracking. 37 patients with normal LV function and 18 patients with ischaemic wall-motion abnorma...
متن کاملA quantitative investigation on lung tumor site on its motion tracking in radiotherapy with external surrogates
Introduction: In external beam radiotherapy each effort is done to deliver 3D dose distribution onto the tumor volume uniformly, while minimizing the dose to healthy organs at the same time. Radiation treatment of tumors located at thorax region such as lung and liver has a challenging issue during target localization since these tumors move mainly due to respiration. There are...
متن کاملMultiple Target Tracking With a 2-D Radar Using the JPDAF Algorithm and Combined Motion Model
Multiple target tracking (MTT) is taken into account as one of the most important topics in tracking targets with radars. In this paper, the MTT problem is used for estimating the position of multiple targets when a 2-D radar is employed to gather measurements. To do so, the Joint Probabilistic Data Association Filter (JPDAF) approach is applied to tracking the position of multiple targets. To ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2010