Finite element analysis of myocardial diastolic function using three-dimensional echocardiographic reconstructions: application of a new method for study of acute ischemia in dogs.

نویسندگان

  • D D McPherson
  • D J Skorton
  • S Kodiyalam
  • L Petree
  • M P Noel
  • R Kieso
  • R E Kerber
  • S M Collins
  • K B Chandran
چکیده

The effect of acute myocardial ischemia on the myocardial elastic modulus has been a matter of controversy. To evaluate this question, diastolic elastic modulus was assessed by finite element analysis of left ventricular geometry using three-dimensional echocardiographic reconstructions and right and left ventricular pressure recordings. Elastic properties were estimated before and after coronary occlusion in 6 open-chest dogs. Elastic modulus values were derived by means of a computer program that determined the global elastic modulus that best predicted the diastolic changes in left ventricular geometry. In the finite element analysis after coronary occlusion, two analyses were performed: one utilizing the control elastic modulus for all segments of the left ventricle and one in which ischemic (dyskinetic) segments were assigned a higher elastic modulus. Results showed that the control elastic modulus was a poor predictor of diastolic left ventricular expansion after coronary occlusion. The finite element analysis in which the ischemic segments were assigned a higher elastic modulus better predicted ischemic diastolic wall motion patterns. Error values (difference between predicted and actual left ventricular segmental diastolic motion) were: control, 1.9 +/- 0.3 mm (mean +/- SD), ischemia, 2.9 +/- 0.5 mm, and 2.2 +/- 0.4 mm using the stiffer elastic modulus for ischemic segments. Error values were significantly higher (p less than 0.05) under ischemic conditions when the control elastic modulus was uniformly applied compared with control and ischemia with dyskinetic segments assigned a higher elastic modulus. From these data, it is concluded that the myocardial diastolic elastic modulus is increased by ischemia and that this approach may allow clinical assessment of intrinsic muscle stiffness.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Time-Discontinuous Finite Element Analysis of Two-Dimensional Elastodynamic Problems using Complex Fourier Shape Functions

This paper reformulates a time-discontinuous finite element method (TD-FEM) based on a new class of shape functions, called complex Fourier hereafter, for solving two-dimensional elastodynamic problems. These shape functions, which are derived from their corresponding radial basis functions, have some advantages such as the satisfaction of exponential and trigonometric function fields in comple...

متن کامل

Modified Fixed Grid Finite Element Method to Solve 3D Elasticity Problems of Functionally Graded Materials

In the present paper, applicability of the modified fixed grid finite element method in solution of three dimensional elasticity problems of functionally graded materials is investigated. In the non-boundary-fitted meshes, the elements are not conforming to the domain boundaries and the boundary nodes which are used in the traditional finite element method for the application of boundary condit...

متن کامل

Echocardiographic Evaluation of left Ventricular Function and Geometry in Pediatric Patients with Kidney Transplantation

Extended abstract Echocardiographic Evaluation of Left Ventricular Function and Geometry in Pediatric Patients with Kidney Transplantation Cardiovascular disease (CVD) is an important, leading cause of mortality and morbidity in patients with chronic kidney disease (CKD) as well as in renal transplant recipients. Cardiovascular complications become more important in children because of the i...

متن کامل

Experimental evaluation of the extent of myocardial dyssynergy and infarct size by two-dimensional echocardiography.

The extent of left ventricular (LV) dyssynergy was assessed noninvasively in 19 dogs with two-dimensional echocardiographic short-axis sections during myocardial ischemia and infarction. After coronary occlusion, two-dimensional echocardiography uniformly indicated an increase in LV end-diastolic volume and a decrease in LV ejection fraction. Two-dimensional echocardiographic measurements of dy...

متن کامل

Geometrically nonlinear analysis of axially functionally graded beams by using finite element method

The aim of this paper is to investigate geometrically nonlinear static analysis of axially functionally graded cantilever beam subjected to transversal non follower load. The considered problem is solved by finite element method with total Lagrangian kinematic approach. The material properties of the beam vary along the longitudinal direction according to the power law function. The finite elem...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation research

دوره 60 5  شماره 

صفحات  -

تاریخ انتشار 1987