Plastic processing of cemented hip joint replacement specimens.
نویسندگان
چکیده
منابع مشابه
Hip Arthroplasty and its Revision in a Child: Case Report and Literature Review
Juvenile idiopathic arthritis is the leading cause of hip replacement in young children. However, arthroplasty in this population is challenging with several concerns about quality of the growing bone, young age for revision surgery, and difficulties in potential several revisions. In this study we introduce a case of a 12-year old who is one of the youngest patients to undergo revision hip art...
متن کاملThe Ring uncemented plastic-on-metal total hip replacement. Five-year results.
The Ring plastic-on-metal total hip replacement was introduced with the intention of combining the advantages of the cemented low-friction arthroplasty with those of a cementless system. Fourteen hundred and eighty-eight of these procedures have been reviewed. The results of a two to seven-year follow-up, and of a group which has completed at least five years are presented. There was an excelle...
متن کاملA preliminary hip joint simulator study of the migration of a cemented femoral stem.
A hip joint simulator that can be used to evaluate the outcome of the cemented total hip replacement has been designed, manufactured and evaluated. The simulator produces motion of a cemented hip construct in the extension/flexion plane, with a socket to rotate internal/externally. At the same time a dynamic loading cycle is applied to the construct. A validation test was performed on a cemente...
متن کاملCemented versus uncemented femoral components in the ring hip prosthesis.
A prospective, randomised and independently assessed trial of the Ring UPM total hip replacement showed that the quality of the early result was better if the femoral prosthesis was cemented than if it was not. More patients with cemented prostheses were painfree at four months (58% cemented:42% uncemented) and at one year (63% cemented:50% uncemented), but at two years pain relief was equal in...
متن کاملCement as a risk factor for deep-vein thrombosis. Comparison of cemented TKR, uncemented TKR and cemented THR.
A total of 110 total knee replacements (TKRs) was randomised to receive either a cemented or an uncemented prosthesis. Postoperative venography at five to seven days was used to compare the prevalence, site and size of deep-vein thrombosis (DVT). We also compared the findings with those of postoperative venography in a group of patients with cemented total hip replacements (THRs). The total pre...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of clinical pathology
دوره 39 3 شماره
صفحات -
تاریخ انتشار 1986