Photoconductance quantization in a single-photon detector
نویسندگان
چکیده
We have made a single-photon detector that relies on photoconductive gain in a narrow electron channel in an AlyGa12yAs/GaAs two-dimensional electron gas. Given that the electron channel is one dimensional, the photoinduced conductance has plateaus at multiples of the quantum conductance 2e/h . Superimposed on these broad conductance plateaus are many sharp, small, conductance steps associated with single-photon absorption events that produce individual photocarriers. This is a first step toward a photoconductive detector that could measure a single photon, while safely storing and protecting the spin degree of freedom of its photocarrier, but we have not actually achieved that goal.
منابع مشابه
Quantum plasmonics: Symmetry-dependent plasmon-molecule coupling and quantized photoconductances
We investigate photoinduced electron transport through nanoparticle dimers connected by linear and ringlike molecules. The two model junctions exhibit similar absorption but distinct photoconductance. The linear-chain junction shows a constant conductance that is independent of photon energies. In contrast, the ring molecules show quantized conductance resonances at energies corresponding to th...
متن کاملAssessment of basic physical and dosimetric parameters of synthetic single-crystal diamond detector and its use in Leksell Gamma Knife and CyberKnife small radiosurgical fields
Background: To determine the basic physical and dosimetric properties of a new synthetic single-crystal diamond detector and its application for relative small field dosimetry. Materials and Methods: The pre-irradiation dose required to stabilize detector response, dose rate dependence, photon and electron energy dependence, temperature dependence and angular dependence of MicroDiamond detector...
متن کاملPhoton dosimetry based on selective data sampling for the NaI(TL) detector
Radiation detection is essential for determining of radiation dose. Depend on the detector and dosimetry method, detection process is performed in different levels. Pulse counting is the first level of detection. Typically, the output of a radiation detector for determining value of the radiation dose cannot be used directly. Through changing the response function or the readout detector, is tr...
متن کاملMeasurement of stereotactic beam data of 9 MV X-rays using diode detector
Background: Radiosurgery is a focal brain irradiation technique that delivers, usually in a single session, high dose of ionizing radiation. The presence of lateral electronic disequilibrium and steep dose gradients in small fields demands special attention to the selection of a suitable detector with respect to its size, composition and response. Materials and Methods : Small circular fields w...
متن کاملInvestigation of surface and buildup region doses for 6 MV high energy photon beams in the presence of a thermoplastic mask
Background: The accuracy and the reproducibility of radiotherapy can be provided by using immobilization devices such as thermoplastic masks. In head and neck cancer radiotherapy, the patients are mostly immobilized by using thermoplastic masks. In this study, the effect of the thermoplastic mask to the surface and buildup region doses was investigated by using Markus parallel plate ion chamber...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2002