Evaluation and clinical application of a dextran-charcoal method for measuring bound testosterone in human plasma.

نویسندگان

  • R K Tcholakian
  • G M Jones
  • B M Sanborn
  • L J Rodriguez-Rigau
  • G G Reimondo
چکیده

A method for rapidly determining bound and free testosterone in human plasma is evaluated and described, in which dextran-coated charcoal is used to separate bound and free testosterone. Intra- and inter-assay CV's were 1.9 and 3.8%, respectively. At least 50% of the "bound" testosterone was associated with species that behaved like sex steroid hormone-binding globulin on Sephadex G-25 chromatography and polyacrylamide gel electrophoresis. Bound and free testosterone concentrations were determined in normal men, normal women (during the menstrual cycle and during normal pregnancy), and in women with various degrees of hirsutism. We conclude that determining the circulating proportions of bound and free testosterone is helpful in the diagnostic evaluation of hirsutism in women, and in the investigation of normal and pathological conditions where androgen concentrations may be altered.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A SPECIFIC, SENSITIVE, AND ONE-STEP EXTRACTION RADIOIMMUNOASSAY OF TESTOSTERONE FOR CLINICAL DIAGNOSIS

Testosterone was measured using antibodies raised against testosterone II B-carboxymethyl ether bovine serum albmin (T-IIB-CME-BSA) and testosterone 3- O-carboxymethyl oxime-BSA as immunogen. The antibody produced in this study exhibits minimal cross reactivity with the structurally related steroids specially 5 dihydrotestosterone (5 DHD. This allows to ommit the clean up step and measure ...

متن کامل

[Free testosterone index: comparison with plasma free testosterone].

Blood-free testosterone indices were measured among 28 normal men (age; 24-48 yrs.), 20 normal women (20-36 yrs.), 18 pregnant women (22-31 yrs.), 17 males with hypogonadism (23-56 yrs.), 17 males with chronic hepatitis (20-42 yrs.), 24 males with liver cirrhosis (29-68 yrs.), 34 males with hyperthyroidism (20-42 yrs.) and 7 hirsute women (18-31 yrs.), and these were compared with the plasma co...

متن کامل

Development and Application of a Validated Liquid Chromatography-Mass Spectrometry Method for the Determination of Dexchlorpheniramine Maleate in Human Plasma

     A convenient liquid chromatographic-single Quadrupole mass spectrometric (LC-MS) method was developed and validated for dexchlorpheniramine maleate (INN name: chlorphenamine) determination in human plasma. The need for just a single liquid-liquid extraction with ethyl acetate and being highly sensitive were the advantages of this method. The linearity was also excellent over the range of 1...

متن کامل

Evaluation and application of magnetizable charcoal for separation in radioimmunoassays.

We compared conventional charcoal separation of antibody-bound and free antigen with a novel method involving magnetizable particles containing charcoal. The magnetizable charcoal separation method was as effective as the conventional method for a wide range of radioimmunoassays, including those for several steroids and small polypeptide hormones. In a detailed comparison of conventional vs. ma...

متن کامل

Evaluation of biochemical methods performance in clinical laboratories: is this performance suitable for clinical application?

Background: Clinical application of the test results are profoundly influenced by laboratory errors. Nowadays, the best way to evaluate the performance of a method is to determine its sigma scale according to total allowable error (TEa) and analytical errors, including random and systematic errors. In this study, the performance of the measuring kits for biochemical analytes belonging to Pars A...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Clinical chemistry

دوره 26 1  شماره 

صفحات  -

تاریخ انتشار 1980