Computational enhancements to fluence map optimization for total marrow irradiation using IMRT
نویسندگان
چکیده
The fluence map optimization (FMO) problem is a core problem in intensity modulated radiation therapy (IMRT) treatment planning. Although it has been studied extensively for site-specific treatment planning, few studies have examined efficient computational methods for solving it for intensity modulated total marrow irradiation (IM-TMI) planning; few studies have also looked at exploiting prior beamlet information to solve the FMO problem in a beam orientation optimization context. In this study, we consider different types of line search strategies and different types of warm-start techniques to improve the speed with which the FMO problem for IM-TMI is solved and the quality of the end solution. We also consider a parallelism-enhanced algorithm to solve the FMO problem for IM-TMI treatment planning with a large number of beams (36 equispaced beams at each of 11 isocenters, for a total of 396 beams). We show that the backtracking line search strategy with step reduction exhibits the best performance and that using either of the two types of warm-start techniques which we consider leads to significant improvements in both solution time and quality. We also provide results for the aforementioned 396-beam plan and show that 30-beam solutions obtained using beam orientation optimization attain a comparable level of quality as this larger solution. & 2011 Elsevier Ltd. All rights reserved.
منابع مشابه
FLUENCE MAP OPTIMIZATION IN INTENSITY MODULATED RADIATION THERAPY FOR FUZZY TARGET DOSE
Although many methods exist for intensity modulated radiotherapy (IMRT) fluence map optimization for crisp data, based on clinical practice, some of the involved parameters are fuzzy. In this paper, the best fluence maps for an IMRT procedure were identifed as a solution of an optimization problem with a quadratic objective function, where the prescribed target dose vector was fuzzy. First, a d...
متن کاملFluence Map Optimization in IMRT Cancer Treatment Planning and A Geometric Approach
Intensity-modulated radiation therapy (IMRT) is a state-of-the-art technique for administering radiation to cancer patients. The goal of a treatment is to deliver a prescribed amount of radiation to the tumor, while limiting the amount absorbed by the surrounding healthy and critical organs. Planning an IMRT treatment requires determining fluence maps, each consisting of hundreds or more beamle...
متن کاملIterative Solution Methods for Beam Angle and Fluence Map Optimization in Intensity Modulated Radiation Therapy Planning
We present computational approaches for optimizing beam angles and fluence maps in Intensity Modulated Radiation Therapy (IMRT) planning. We assume that the number of angles to be used for the treatment is given by the treatment planner. A mixed integer programming (MIP) model and a linear programming (LP) model are used to find an optimal set of beam angles and their corresponding fluence maps...
متن کاملNeighborhood search approaches to non-coplanar beam orientation optimization for total marrow irradiation using IMRT
We consider the beam orientation optimization (BOO) problem for total marrow irradiation (TMI) treatment planning using intensity modulated radiation therapy (IMRT). Currently, IMRT is not widely used in TMI treatment delivery; furthermore, the effect of using non-coplanar beam orientations is not known. We propose and implement several variations of a single neighborhood search algorithm that ...
متن کاملIterative Approach for Automatic Beam Angle Selection in Intensity Modulated Radiation Therapy Planning
Introduction: Beam-angle optimization (BAO) is a computationally intensive problem for a number of reasons. First, the search space of the solutions is huge, requiring enumeration of all possible beam orientation combinations. For example, when choosing 4 angles out of 36 candidate beam angles, C36 = 58905 possible combinations exist. Second, any change in a beam 4 config...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Computers & OR
دوره 40 شماره
صفحات -
تاریخ انتشار 2013