Mapping of atrial activation with a noncontact, multielectrode catheter in dogs.

نویسندگان

  • A Kadish
  • J Hauck
  • B Pederson
  • G Beatty
  • C Gornick
چکیده

BACKGROUND Endocardial mapping of sustained arrhythmias has traditionally been performed with a roving diagnostic catheter. Although this approach is adequate for many tachyarrhythmias, it has limitations. The purpose of this study was to evaluate a novel noncontact mapping system for assessing atrial tachyarrhythmias. METHODS AND RESULTS The mapping system consists of a 9F multielectrode-array balloon catheter that has 64 active electrodes and ring electrodes for emitting a locator signal. The locator signal was used to construct a 3-dimensional right atrial map; it was independently validated and was highly accurate. Virtual electrograms were calculated at 3360 endocardial sites in the right atrium. We evaluated right atrial activation by positioning the balloon catheter in the mid right atrium via a femoral venous approach. Experiments were performed on 12 normal mongrel dogs. The mean correlation coefficient between contact and virtual electrograms was 0.80+/-0.12 during sinus rhythm. Fifty episodes of atrial flutter induced in 11 animals were evaluated. In the majority of experiments, complete or almost complete reentrant circuits could be identified within the right atrium. Mean correlation coefficient between virtual and contact electrograms was 0.85+/-0.17 in atrial flutter. One hundred fifty-six episodes of pacing-induced atrial fibrillation were evaluated in 11 animals. Several distinct patterns of right atrial activation were seen, including single-activation wave fronts and multiple simultaneous-activation wave fronts. Mean correlation coefficient between virtual and contact electrograms during atrial fibrillation was 0.81+/-0.18. The accuracy of electrogram reconstruction was lower at sites >4.0 cm from the balloon center and at sites with a high spatial complexity of electrical activation. CONCLUSIONS This novel noncontact mapping system can evaluate conduction patterns during sinus rhythm, demonstrate reentry during atrial flutter, and describe right atrial activation during atrial fibrillation. The accuracy of electrogram reconstruction was good at sites <4.0 cm from the balloon center, and thus the system has the ability to perform high-resolution multisite mapping of atrial tachyarrhythmias in vivo.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Simultaneous noncontact mapping of left atrium in patients with paroxysmal atrial fibrillation.

BACKGROUND Catheter ablation of pulmonary vein ectopic foci is a potentially curative treatment strategy for patients with atrial fibrillation. However, identification of arrhythmogenic pulmonary veins with conventional mapping is difficult, especially in patients with rare focal activity, multiple active foci, or extrapulmonary foci. The present study was designed to investigate use of simulta...

متن کامل

Atrial tachycardia after ablation of persistent atrial fibrillation: identification of the critical isthmus with a combination of multielectrode activation mapping and targeted entrainment mapping.

BACKGROUND Atrial tachycardia (AT) that develops after ablation of atrial fibrillation often poses a more difficult clinical situation than the index arrhythmia. This study details the use of an impedance-based electroanatomic mapping system (Ensite NavX) in concert with a specialized multielectrode mapping catheter for rapid, high-density atrial mapping. In this study, this activation mapping ...

متن کامل

Simultaneous Epicardial and Noncontact Endocardial Mapping of the Canine Right Atrium: Simulation and Experiment

Epicardial high-density electrical mapping is a well-established experimental instrument to monitor in vivo the activity of the atria in response to modulations of the autonomic nervous system in sinus rhythm. In regions that are not accessible by epicardial mapping, noncontact endocardial mapping performed through a balloon catheter may provide a more comprehensive description of atrial activi...

متن کامل

Comparison of noncontact and electroanatomic mapping to identify scar and arrhythmia late after the Fontan procedure.

BACKGROUND The right atrium late after the Fontan procedure is characterized by multiple complex arrhythmia circuits. We performed simultaneous electroanatomic and noncontact mapping to assess the accuracy of both systems to identify scar and arrhythmia. METHODS AND RESULTS Mapping was performed in 26 patients aged 26.8+/-8.9 years, 18.7+/-4.4 years after Fontan surgery. The area and site of ...

متن کامل

Validation of a new noncontact catheter system for electroanatomic mapping of left ventricular endocardium.

BACKGROUND Improvements in cardiac mapping are required to advance our understanding and treatment of arrhythmias. This study validated a new noncontact multielectrode array catheter and accompanying analysis system to provide electroanatomic mapping of the entire left ventricular (LV) endocardium during a single beat. METHODS AND RESULTS A 9F 64-electrode balloon array catheter with an infla...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Circulation

دوره 99 14  شماره 

صفحات  -

تاریخ انتشار 1999