Phased Array Imaging in Mouse Hearts using an 8-Channel Phased Array Coil at 9.4 Tesla
نویسندگان
چکیده
Introduction: Cardiac magnetic resonance imaging (CMR) in surgically or genetically modified mice is typically performed using single dedicated volume or surface coils. The development of coil arrays to speed-up CMR becomes more challenging with increasing magnetic field strength and reduced bore size of the magnet. While the use of coil arrays for cardiac MR exams of the human heart is well established in the clinic, only very few studies have reported on the use of 2-4 element arrays for MR on the mouse heart (1,2). This work presents first results for CMR in mice in vivo at 9.4T using a volume-coil-transmit/8-channel-volume-receive-array combination, and performs signal-to-noise-ratio (SNR) comparisons for different regions of heart as a function of selected coilelements. Methods: The coil-array consists of 8 elements (id 35 mm, length 32.5 mm) arranged cylindrically inside a linear-driven volume coil (id 67 mm, length 82 mm/od 115 mm). Imaging was performed on a horizontal 9.4T MR system comprising a VNMRS DirectDrive console with eight receivers (Varian Inc., USA) and a 600 mT/m gradient system. Mice were positioned prone and off-centered in a home-built mouse cradle, with the chest resting as close as possible on the lower coil-elements. Double-gated in vivo MR images of the three main axes of the heart were acquired using a segmented gradient echo (GE) sequence (TE/TR=1.2/3 ms, 8 segments per cardiac cycle, FOV 30x30 mm, 128x128), and a fast multi-frame GE sequence (TE/TR=1.79/4.6ms, NAE=1, α=15°, FOV 25.6x25.6 mm, 256x256) on a mid-ventricular short-axis slice in three normal mice (28 ± 3 g). Sum-of-square reconstruction (SOS) and SNRmeasurements (using the BOOTLEG method (3,4)) as a function of coil-elements (arranged descending according to their signal contribution) were performed in an end-diastolic frame of the cine train for anterior, lateral, posterior, septal left-ventricular and for blood, respectively. Results: Single coil elements showed high isolation under in vivo conditions (max. noise correlation 28%, mean 12%). Overall decoupling of each pair of coil elements was better than 16 dB on the bench, excluding preamplifier decoupling (typically an additional 20 dB). In Fig. 1, the SOS of all eight coil-elements for (A) the long-axis two-chamber and (B) long-axis four-chamber of the heart are shown. Figure 2 depicts (A-H) individual coil images, and (I) SOS of an end-diastolic frame (in plane resolution 50 μm, slice thickness 1 mm) out of the cine train. The scale bars in both Figures correspond to 5 mm. Figure 3 shows the results for the SNR measurements as a function of the number of contributing coils averaged over all voxels in the respective compartment of the three mice (mean ± SD). The optimum coil number was 8 for all compartments with the main contribution from the 3 anterior coil elements.
منابع مشابه
Phased array ultrasonic imaging using an improved beamforming based total focusing method for non destructive test
One of the novel ultrasonic phased array based scanning methods for ultrasonic imaging in non-destructive test is total focusing method (TFM). This method employs maximum available information of the phased array elements and leads to an improved defect detection accuracy compared to conventional scanning methods. Despite its high detection accuracy, TFM behaves weak in distinguishing the real ...
متن کاملAccelerated Cardiac Magnetic Resonance Imaging in the Mouse Using an Eight-Channel Array at 9.4 Tesla
MRI has become an important tool to noninvasively assess global and regional cardiac function, infarct size, or myocardial blood flow in surgically or genetically modified mouse models of human heart disease. Constraints on scan time due to sensitivity to general anesthesia in hemodynamically compromised mice frequently limit the number of parameters available in one imaging session. Parallel i...
متن کاملPhased array ultrasonic imaging using an improved beamforming based total focusing method for non destructive test
One of the novel ultrasonic phased array based scanning methods for ultrasonic imaging in non-destructive test is total focusing method (TFM). This method employs maximum available information of the phased array elements and leads to an improved defect detection accuracy compared to conventional scanning methods. Despite its high detection accuracy, TFM behaves weak in distinguishing the real ...
متن کاملComparison of Pelvic Phased-Array versus Endorectal Coil Magnetic Resonance Imaging at 3 Tesla for Local Staging of Prostate Cancer
PURPOSE Several studies have demonstrated the superiority of endorectal coil magnetic resonance imaging (MRI) over pelvic phased-array coil MRI at 1.5 Tesla for local staging of prostate cancer. However, few have studied which evaluation is more accurate at 3 Tesla MRI. In this study, we compared the accuracy of local staging of prostate cancer using pelvic phased-array coil or endorectal coil ...
متن کاملA 4-channel 3 Tesla phased array receive coil for awake rhesus monkey fMRI and diffusion MRI experiments.
Awake monkey fMRI and diffusion MRI combined with conventional neuroscience techniques has the potential to study the structural and functional neural network. The majority of monkey fMRI and diffusion MRI experiments are performed with single coils which suffer from severe EPI distortions which limit resolution. By constructing phased array coils for monkey MRI studies, gains in SNR and anatom...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2008