Image Quality Assessment of CR Systems
نویسندگان
چکیده
Computed Radiography exposure experiments on welded plate sections were performed to demonstrate that the requirements for pressure vessels weld inspection according to EN1435 or EN14784-2 class B can be achieved. The representative comparative studies of the image qualities were performed with standardized image quality indicators and image evaluation procedures on both film and digital radiographs. Recommendations for weld inspections with CR systems are drawn from the results. It is demonstrated that present CR systems can be used for weld inspection and produce images with testing class B if the selected X-ray tube voltage is reduced compared with the max. voltage of EN 14784-2 and set equivalent to maximum X-ray voltage values for steel as defined in the radioscopic standard EN 13068-3. The work was part of the European “Filmfree” Project promoted during the 6’th framework.
منابع مشابه
Image quality assessment in digital radiography systems- A Pehamed FLUORAD A+D phantom study
Introduction: The use of digital radiography systems has become more common all around the world. Ideal situation in radiography is to maximize the image quality while minimizing the patient dose. The purpose of this study was to compare image quality and radiation dose in different digital radiography systems. Materials and Methods: Images of Pehamed FLUORAD ...
متن کاملQuality comparison of direct digital panoramic radiography and computed radiography panoramic
BACKGROUND AND AIM: Digital panoramic X-ray images can be captured using photostimulable phosphors or solid-state detectors (i.e. charge-coupled devices and Flat-Panels). The first category is defined as computed radiography (CR) or semi-direct radiography. The second technology that uses solid-state detectors is known as direct digital radiography (DDR). Both of these technologies have their o...
متن کاملThe Practice of Chest Radiography Using Different Digital Imaging Systems: Dose and Image Quality
Introduction: The study was undertaken to evaluate the practice of chest radiography using different digital imaging systems and its influence on dose and image quality. Materials and Methods: The study was carried out in two hospitals from March 2016 to June 2016. Sixty ambulatory patients aged 21 to 60 years who were able to cooperate without difficulty and weighed between 60 to 80 kg were ...
متن کاملEntrance skin dose assessment of selected computed radiography facilities in Ghana
Background: The basic challenge with computed radiography (CR) systems is the large dynamic range which provides an opportunity for radiographers to gradually increase exposure factors and still produce good image quality, a practice that can lead to dose creep. Materials and Methods: The aim of this study was to establish the entrance skin dose (ESD) values for nine selected examinations in t...
متن کاملPerformance Evaluation of Medical Image Retrieval Systems Based on a Systematic Review of the Current Literature
Background and Aim: Image, as a kind of information vehicle which can convey a large volume of information, is important especially in medicine field. Existence of different attributes of image features and various search algorithms in medical image retrieval systems and lack of an authority to evaluate the quality of retrieval systems, make a systematic review in medical image retrieval system...
متن کاملQuantitative assessment of computed radiography quality control parameters.
Quality controls for testing the performance of computed radiography (CR) systems have been recommended by manufacturers and medical physicists' organizations. The purpose of this work was to develop a set of image processing tools for quantitative assessment of computed radiography quality control parameters. Automatic image analysis consisted in detecting phantom details, defining regions of ...