Pupil Tracking for Real-Time Motion Corrected Anterior Segment Optical Coherence Tomography

نویسندگان

  • Oscar M. Carrasco-Zevallos
  • Derek Nankivil
  • Christian Viehland
  • Brenton Keller
  • Joseph A. Izatt
چکیده

Volumetric acquisition with anterior segment optical coherence tomography (ASOCT) is necessary to obtain accurate representations of the tissue structure and to account for asymmetries of the anterior eye anatomy. Additionally, recent interest in imaging of anterior segment vasculature and aqueous humor flow resulted in application of OCT angiography techniques to generate en face and 3D micro-vasculature maps of the anterior segment. Unfortunately, ASOCT structural and vasculature imaging systems do not capture volumes instantaneously and are subject to motion artifacts due to involuntary eye motion that may hinder their accuracy and repeatability. Several groups have demonstrated real-time tracking for motion-compensated in vivo OCT retinal imaging, but these techniques are not applicable in the anterior segment. In this work, we demonstrate a simple and low-cost pupil tracking system integrated into a custom swept-source OCT system for real-time motion-compensated anterior segment volumetric imaging. Pupil oculography hardware coaxial with the swept-source OCT system enabled fast detection and tracking of the pupil centroid. The pupil tracking ASOCT system with a field of view of 15 x 15 mm achieved diffraction-limited imaging over a lateral tracking range of +/- 2.5 mm and was able to correct eye motion at up to 22 Hz. Pupil tracking ASOCT offers a novel real-time motion compensation approach that may facilitate accurate and reproducible anterior segment imaging.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Analysis of anterior segment dynamics using anterior segment optical coherence tomography before and after laser peripheral iridotomy.

OBJECTIVE To evaluate changes in the speed of pupil constriction and in anterior segment parameters after laser peripheral iridotomy (LPI) in patients with angle closure using anterior segment optical coherence tomography. METHODS In this prospective observational study, videos of pupil and anterior segment changes in response to illumination were captured with real-time video recording using...

متن کامل

Quantitative OCT-based corneal topography in keratoconus with intracorneal ring segments

Custom high-resolution high-speed anterior segment spectral domain Optical Coherence Tomography (OCT) was used to characterize three-dimensionally (3-D) corneal topography in keratoconus before and after implantation of intracorneal ring segments (ICRS). Previously described acquisition protocols were followed to minimize the impact of the motions of the eye. The collected set of images was cor...

متن کامل

Real-time optical coherence tomography of the anterior segment at 1310 nm.

BACKGROUND Recent advances in high-speed scanning technology have enabled a new generation of optical coherence tomographic (OCT) systems to perform imaging at video rate. Here, a handheld OCT probe capable of imaging the anterior segment of the eye at high frame rates is demonstrated for the first time. OBJECTIVE To demonstrate real-time OCT imaging of anterior segment structures. DESIGN S...

متن کامل

Subluxed traumatic cataract: optical coherence tomography findings and clinical management

This case report describes the optical coherence tomography (OCT) findings and clinical management of a patient with traumatic subluxed cataract. The patient presented with a traumatic subluxed cataract and vitreous prolapse into the anterior chamber. The anterior segment OCT showed vacuoles in the anterior subcapsular regions of the crystalline lens. The patient was treated with pars plana len...

متن کامل

Optical Coherence Tomography (OCT) of the Anterior Eye Segment

Description of Procedure or Service Optical coherence tomography (OCT) is a high resolution method of imaging the ocular structures. OCT for the anterior eye segment is being evaluated as a non-invasive diagnostic and screening tool for the detection of angle closure glaucoma, to assess corneal thickness and opacity, evaluate pre-surgical and postsurgical anterior chamber anatomy, calculate int...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 11  شماره 

صفحات  -

تاریخ انتشار 2016