Electrochemical Determination of Ebastine in Tablet Dosage Forms at Hanging Mercury Drop Electrode

نویسندگان

  • Sunil Kumar
  • Nagaraju
چکیده

The electrochemical behaviour of ebastine was studied at hanging mercury drop electrode using cyclic voltammetry and differential pulse voltammetry. The molecule shows a single, well defined reduction peak due to the reduction of carbonyl group. The voltammetric conditions were optimized with respect to maximum peak signals. The linearity between the peak signal and the concentration of ebastine over the concentration range of 2.0 x 10 M – 1.0 x10 M was established .The detection and quantitation limits were found to be 0.48 x 10 M and 1.60 x 10 M respectively. The developed method was employed for the determination of ebastine in tablet dosage forms.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Simultaneous Voltammetric Determination of Nitazoxanide and Ofloxacin in Pharmaceutical Formulation

A simple, sensitive and highly selective electrochemical method was developed for the simultaneous determination of nitazoxanide and ofloxacin in aqueous media (Britton-Robinson buffer, pH-8.36) on a hanging mercury drop electrode (HMDE) using differential pulse polarography (DPP). Using DPP a separation of about 936 mV between the peak oxidation potentials of nitazoxanide and ofloxacin present...

متن کامل

Cathodic adsorptive stripping voltammetric determination of prednisolone in pharmaceutical preparation and human urine.

Differential pulse cathodic adsorptive stripping voltammetric method was developed for the determination of prednisolone based on electrochemical reduction of the drug at a hanging mercury drop electrode (HMDE) in 0.04 M Britton-Robinson buffer pH 3.5. The peak current varied linearly over the concentration range 7.21-144.2 ng/ml prednisolone with limit of detection and limit of quantification ...

متن کامل

Cathodic Stripping Voltammetric Determination of Febuxostat in Pharmaceutical Dosage Form and Plasma Samples

Febuxostat FEB was determined by differential pulse “DP” adsorptive stripping voltammetry and hanging mercury drop electrode. In 0.04 mol L Britton-Robinson buffer solution, pH 10, an irreversible electrochemical reaction took place at about -350 mV, and the peak current was linearly varied over the concentration range of 12.5-200 ng mL FEB, with correlation coefficients of 0.9995, after 60 s a...

متن کامل

Adsorptive Stripping Anodic Voltammetric Determination of Thioctic Acid in Bulk and Pharmaceutical Formulations

The electrochemical behavior of thioctic acid at the hanging mercury drop electrode was studied in different supporting electrolytes. In Britton - Robinson buffer pH 3.29, the square - wave adsorptive anodic stripping voltammogram of thioctic acid exhibited a single well - defined anodic peak at about -0.21 V vs Ag/AgCl. The peak response was characterized with respect to pH, preconcentration t...

متن کامل

Modern Electrochemical Methods for Monitoring of Chemical Carcinogens

This contribution is based on our presentation at the 1 International Symposium on Sensor Science, Paris, 16-20 June 2003. It presents recent results regarding the electrochemical determination of submicromolar and nanomolar concentrations of various carcinogenic substances (nitrated polycyclic aromatic hydrocarbons, heterocyclic compounds, azo compounds, aromatic amino compounds, etc.) using b...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2012